MINIPLEX Transponder Product Selection (Continued)
Audio Riser Modules
Model
Description
Dual Channel Analog Audio Riser Module; accepts one or two separate audio signals from
4100-0621
host control panel; mounts in Block B, is controlled by Transponder Interface Module
3-8 Channel Digital Audio Riser Module; similar to analog module, except receives and
4100-0622
decodes a digital input signal with up to eight audio channels; with Non-Alarm Audio input
Analog Emergency Voice/Alarm Communications Equipment, Constant Supervision Compatible*
Model
Description
4100-1361
25 VRMS output
4100-1362
70.07 VRMS output
4100-1312
25 VRMS output
4100-1313
70.7 VRMS output
100 W Analog Amplifiers with Power Supply, Constant Supervision Compatible
Model/Output Voltage
Power Supply Input/Listing
25 VRMS
70.7 VRMS
4100-1314
4100-1315
120 VAC, 60 Hz
4100-1316
4100-1317
120 VAC, 60 Hz
4100-1318
4100-1319
220/230/240 VAC, 50/60 Hz
4100-1320
4100-1321
120 VAC, 60 Hz
4100-1322
4100-1323
120 VAC, 60 Hz
4100-1324
4100-1325
220/230/240 VAC, 50/60 Hz
Digital Emergency Voice/Alarm Communications Equipment*
Model
Description
4100-1363
25 VRMS output
4100-1364
70.07 VRMS output
4100-1326
25 VRMS output
4100-1327
70.7 VRMS output
100 W Digital Amplifiers with Power Supply, Constant Supervision Compatible
Model/Output Voltage
Power Supply Input/Listing
25 VRMS
70.7 VRMS
4100-1328
4100-1329
120 VAC, 60 Hz
4100-1330
4100-1331
120 VAC, 60 Hz
4100-1332
4100-1333
220/230/240 VAC, 50/60 Hz
4100-1334
4100-1335
120 VAC, 60 Hz
4100-1336
4100-1337
120 VAC, 60 Hz
4100-1338
4100-1339
220/230/240 VAC, 50/60 Hz
Options for use with either Analog or Digital Amplifiers
Model
Description
Flex-35/50 Expansion NAC Module; adds three
4100-1245
Class B audio NACs
Flex-35/50 Class A Adapter Module; converts
4100-1246
three on-board NACS to Class A operation
100 W Amplifier Expansion NAC Module; NAC
4100-1248
ratings = 1.5 A, 50 W, or 100 speakers max.
100 W Class A Adapter Module; NAC ratings =
4100-1249
2 A, 50 W, or 100 speakers max.
25 VRMS Output; NAC
4100-1259
rating = 2 A, 50 W, or
100 speakers max.
70.7 VRMS Output; NAC
4100-1260
rating = 0.707 A, 50 W,
or 100 speakers max.
Firefighters Telephone Options*
Model
Description
Expansion Telephone Control Module with three Class B telephone NACS; required when
4100-1272
telephone circuits are mounted in transponder;
4100-1273
Telephone Class A Adapter Module; mounts on 4100-1272; no additional current required
* Refer to document S4100-0034 for additional audio information.
Flex-35, 35 W Amplifier, constant
supervision compatible
Flex-50, 50 W Amplifier, constant
supervision compatible
UL
ULC
UL
UL
ULC
UL
Flex-35, 35 W Amplifier, constant
supervision compatible
Flex-50, 50 W Amplifier, constant
supervision compatible
UL
ULC
UL
UL
ULC
UL
Choose
one per
amplifier
Choose
one per
amplifier
Constant Supervision Adapter
for three NACs; select per
amplifier output; not
compatible with amplifier NAC
expansion modules;
deactivated when on batteries
Details
Includes three on-board
Class B audio NACs;
power is supplied from
an EPS+, EPS, or XPS
Description
Details
Includes six, Class B audio NACs;
Primary
NAC rating = 50 W or 100 speakers
100 W
maximum; 2 A @ 25 VRMS;
Amplifier
1.4 A @ 70.7 VRMS
Backup
Uses the six Class B NACs of primary
100 W
amplifier
Amplifier
Details
Includes three on-board
Class B audio NACs;
power is supplied from
an EPS+, EPS, or XPS
Description
Details
Includes six, Class B audio NACs;
Primary
NAC rating = 50 W or 100 speakers
100 W
maximum; 2 A @ 25 VRMS;
Amplifier
1.4 A @ 70.7 VRMS
Backup
Uses the six Class B NACs of primary
100 W
amplifier
Amplifier
Details and Mounting Reference
Mounts on Flex-35/50 assembly; NAC ratings = 1.5 A, 35/50 W,
or 100 speakers maximum; Supv = 8 mA, Alarm = 60 mA
Mounts on Flex-35/50 assembly; NAC ratings = 2 A, 50 W, or
100 speakers maximum; Supv =10 mA, Alarm = 30 mA
Provides six additional Class B audio NACs, mounts on 100 W
amplifier assembly; Supv = 17 mA, Alarm = 60 mA
Converts six on-board NACs to Class A operation, mounts on
100 W amplifier assembly; Supv = 1 mA, Alarm = 60 mA
Supv = 10 mA
Converts three Class B audio NACS to
on batteries;
Class A or Class B Constant Supervision
Alarm = 35 mA
NACs; mounts on Flex-35/50 or 100 W
Supv = 38 mA
amplifier assembly; use two for the six NACs
on batteries;
on 100 W amplifiers
Alarm = 70 mA
5
Size
Supv.
1 Block
0 mA
1 Block
70 mA
NAC rating = 1.4 A
35 W, or 100
speakers
NAC rating = 0.5 A
NAC rating = 2 A
50 W, or 100
speakers
NAC rating = 0.707 A
ULC
models
have low
battery
dropout
circuit
NAC rating = 1.4 A
35 W, or 100
speakers
NAC rating = 0.5 A
NAC rating = 2 A
50 W, or 100
speakers
NAC rating = 0.707 A
ULC
models
have low
battery
dropout
circuit
Size
Supv.
1 Block
80 mA
Continued on next page
S4100-0103 5/2013
Alarm
15 mA
70 mA
In Use
130 mA

Advertisement

loading

This manual is also suitable for: