UL, ULC, CSFM Listed;
FM Approved *
Features
4100ES Series MINIPLEX transponders allow
remotely located initiating and notification
functions:
Transponder operation is available as standard or with
local mode operation
Communications with the host fire alarm control panel
use the Remote Unit Interface (RUI/RUI+) format
Initiating functions include:
Addressable device support including TrueAlarm
analog sensor compatibility
Conventional initiating device circuit (IDC) support
Notification functions include:
Addressable strobe and horn notification using
enhanced power delivery IDNAC SLCs
Emergency voice/alarm communications
Conventional DC notification appliance circuits (NACs)
Local mode operation provides:
Default local initiating and notification operation in the
event of a communications loss with the host control panel
Enabling of an optional Local Mode Controller with a
local alarm sounder, LED status indicators, and
keyswitch enabled control switches
Support for IDNet addressable devices, addressable and
conventional notification appliances, and default output
tones from local amplifiers
Optional modules include:
Digital or Analog audio riser modules for connection to
system audio signals
Digital or analog input audio amplifiers with integral
on-board NACs
Power supplies with or without battery chargers
City Connect modules and RS-232 ports for printers or
maintenance terminals
Alarm relays, auxiliary relays, additional IDC modules,
and NAC expansion modules
Cabinets are equipped with solid doors (beige or
red) and in one, two, or three bay sizes
Listed to:
UL Std. 864, Fire Detection and Control (UOJZ), and
Smoke Control Service (UUKL)
UL Std. 2017, Process Management Equipment (QVAX)
UL Std. 1076, Proprietary Alarm Units-Burglar (APOU)
UL Std. 1730, Smoke Detector Monitor (UULH)
ULC Std. S527-99
* See pages 4 and 5 for product that is listed as UL or ULC. This product has been approved by
the California State Fire Marshal (CSFM) pursuant to Section 13144.1 of the California Health
and Safety Code. See CSFM Listing 7165-0026:0251 for allowable values and/or conditions
concerning material presented in this document. Additional listings may be applicable; contact
your local Simplex product supplier for the latest status. Listings and approvals under Simplex
Time Recorder Co. are the property of Tyco Fire Protection Products.
4100ES Fire Control Panels
Addressable Fire Detection and Control
MINIPLEX Transponders
MINIPLEX
transponder
IDNet addressable
devices
FIRE
ALARM
PULL
DOWN
Audio NAC
Emergency Operating Instructi ons
4100ES Fire Alarm Control Panel
with Voice Control
Typical 4100ES MINIPLEX System One-Line Drawing
Introduction
4100ES MINIPLEX transponders connect to a host
4100ES Fire Alarm Control Panel using Simplex
unit interface (RUI) communications. At the transponder,
RUI communications are received by the transponder
interface module and translated into the same internal
communications format that is used in the host control
panel.
Remotely located modules. With RUI
communications, the transponder can remotely provide
the same initiating and notification functions that occur at
the host control panel without requiring multiple long
distance wiring runs. Connections to the host panel are
low current communications and audio wiring with
distances up to 2500 ft (762 m).
Additional Reference. Refer to document S4100-0100
and the other documents listed on page 3 for additional
information concerning the extensive initiating and
notification features of the 4100ES fire alarm control
panels.
Addressable strobes
on IDNAC SLC
C
D I S C O N NEC T
A.C . POWE R
AN D
A
B EFORE
B A T TE RY
U
SE RV IC I N G
T
I
O
N
Local mode
Fire Alarm Local Mode Controller
Alarm
Loca l
Mode
CONTROL
Control
Alarm
Silenced
ENABLE
Local
Mode
controller
Active
Alarm
Silenc e
Res et
Po wer
On
A B C
D E F
G H I
Z ONE
S IG
AUX
1
2
3
FB
J K L
M N O
IO
P Q R
IDNe t
4
5
6
Fire A larm
ALARM S
Pr i ori ty 2 Ala rm
S uperv i sory
S Y STEM WARNI NGS
Trou ble
Al arm Si l enced
AC P ower
P
S T U
V W X
A
Y Z /
L
7
8
9
Fire A larm
P rio rity 2
S up v
Troubl e
Al arm
S ystem
' SP ' ( )
, 0 :
Ac k
Ack
Ack
Ack
S i l ence
Reset
NE T
ADDR
0
DEL
E vent
More
Enter
C/Exit
T ime
I nfo
Pre v ious
Menu
E nable
On
N e xt
Arm
Of f
Lamp
Di sable
Di sa rm
A uto
Test
Alarm or Warning Condition
How to Silenc e Building Signals
S yst em indi cat or f lashing . Tone On.
P ress Al arm Si l ence .
How to Ac knowledge / View Events
How to Reset System
P ress ACK locat ed under f lashing indicat or .
P ress S ystem Reset .
Repeat oper ation unt il all events are acknowledged .
P ress Ack t o si l ence t o ne de vice .
Local t one will silence.
On
On
Of f
Of f
A ut o
A ut o
On
On
Of f
Of f
A ut o
A ut o
On
On
Of f
Of f
A ut o
A ut o
On
On
Of f
Of f
A ut o
A ut o
®
remote
S4100-0103 5/2013