Set All Settings To Factory Default; Fixture Test; Fixture Information - Martin ERA 300 Profile User Manual

Table of Contents

Advertisement

Press ENTER to confirm.

Set all settings to factory default

To return all settings to factory default, select DEFAULT SETTINGS and press ENTER to confirm,
FACTORY DEFAULT will show on the display.
Use the UP and DOWN buttons to select NO (cancel) or YES (return all settings except
calibrations to factory defaults).
Press ENTER to confirm (or press MENU to exit without making a change).

Fixture Test

This menu allows you to run self test sequences on the fixture. The test sequences are:
TEST ALL – runs a test sequence through all functions.
TEST DIMMER – just the LED array is tested.
TEST EFFECTS – tests all effects functions within the head.
TEST PAN/TILT – tests the pan/tilt functions..

Fixture Information

This menu allows you to call up the following fixture information in the display.
POWER ON TIME – displays number of hour's fixture has been powered on since manufacture
(not user-resettable).
LED HOURS - displays number of hours fixture LED's have been powered on since manufacture
(not user-resettable).
SW VERSION - displays the currently installed firmware (fixture software) version.
FIXTURE ID – user selectable fixture ID number (default is 0000).
RDM UID – displays the fixtures factory-set unique ID for identification in RDM systems.
TEMPERATURES – provides separate PCB temperature readouts.
Viewing live DMX values
This menu allows you to view the current DMX values for any function.
Select the DMX LIVE menu and press ENTER.
Use the UP and DOWN buttons to select the function you wish to view.
You can select Strobe, Dimmer, Dimmer Fine, Cyan, Magenta, Yellow, Color, Gobo1, RGobo1,
Gobo2, Prism, R-Prism, Iris, Zoom, Focus, Pan, Pan Fine, Tilt, Tilt Fine, Pan/Tilt Speed and
Function.
Setting control values manually
You can manually set control values. This may be useful when testing, or to use the fixture in a
static setting without a DMX controller.
This menu also allows you to reset all functions in case something is out of position.
Reset
To reset functions, go to the MANUAL CONTROL menu and press ENTER. Use the UP and
DOWN buttons to select RESET and press ENTER again.
Use the UP and DOWN buttons to select:
ALL (resets all functions in fixture)
PAN/TILT (resets just the pan/tilt motors)
EFFECTS (resets the effects in the head)
Once you have selected one of the above, press ENTER, then use UP and DOWN to select YES,
then press ENTER to activate.