Advertisement

Quick Links

m a r t i n
a r c h i t e c t u r a l
Cyclo 04 DMX

Advertisement

Table of Contents
loading

Summary of Contents for Martin CYCLO 04 DMX

  • Page 1 Cyclo 04 DMX...
  • Page 2 © 2003 Martin Professional A/S, Denmark. All rights reserved. No part of this manual may be reproduced, in any form or by any means, with- out permission in writing from Martin Professional A/S, Denmark. Printed in Denmark. P/N 35000131, Rev A...
  • Page 3: Table Of Contents

    ........20 PROTOCOL DMX ......21 PECIFICATIONS YCLO Cyclo 04 DMX user manual...
  • Page 4: Introduction

    NTRODUCTION Thank you for selecting the Martin Cyclo 04 DMX. The Cyclo 04 DMX is a DMX-controllable, fluorescent color changer. This fixtures is designed to be used for cove lighting, perimeter lighting, light walls, behind semi- transparent materials, or any place where room is restricted.
  • Page 5 • Provide a minimum clearance of 0.1 meters (4 inches) around the fixture. • Do not modify the fixture or install other than genuine Martin parts. • Do not operate the fixture if the ambient temperature (Ta) exceeds 40° C (104°...
  • Page 6: Installation

    200-250V AC 50/60 Hz Category 5 DMX network DMX control device To mount the fixture: 1 Loosen the two Philips screws holding the mounting plate to the fixture. 2 Remove the mounting plate from the fixture. Cyclo 04 DMX user manual...
  • Page 7: Ac Power

    (earth) to ensure that the power leakage is able to run off. You can power Cyclo 04 DMX fixtures by wiring them in series. The internal wiring of the fixtures carries AC power through the fixture. Male and female Ensto connectors are provided at opposite ends of the fixture for input and output cables.
  • Page 8: Data Linking Multiple Fixtures

    Cyclo 04 DMX fixtures can be powered in series with other Cyclo 04 DMX fixtures of the same type. When doing this be sure to use a power cable that is able to handle the 0.56A that is drawn by each fixture in the series.
  • Page 9 The: RJ-45 sockets in the Cyclo 04 DMX are wired as follows - pins 7 & 8 to ground, pin 2 to signal - (cold), and pin 1 to signal + (hot).
  • Page 10: Fluorescent Tubes

    C r ea t i ng th e da ta link 1 Connect the RJ-45 connector on the Cyclo 04 DMX to the RJ-45 connector on the next Cyclo 04 DMX. 2 Continue connecting fixtures output to input. Up to 32 devices may be connected on a serial link.
  • Page 11: Tand Alone Operation

    TAND ALONE OPERATION In stand-alone mode, individual Cyclo 04 DMX fixtures can run a set of pre- programmed shows without an external controller. Multiple Cyclo 04 DMX fixtures can also be linked together and scene changes on all fixtures can be synchronously triggered by a “master”...
  • Page 12: Dip-Switch Settings In Stand-Alone Mode

    D I P - S W I T C H S E T T I N G S I N S T A N D - A L O N E M O D E Function White Green Blue 5 & 6 Program speed Pin 6 Pin 5...
  • Page 13 The synchronization signal is the same as used by other Mar tin Architectural products, so this enables the stand-alone functionality to be used with a range of other Martin products. To have a single fixture run alone, it must be set to master. Slave fixtures must not be connected to more than one master.
  • Page 14: Program Examples

    P R O G R A M E X A M P L E S In all programs in these examples each scene lasts for 1 second at full speed. The following symbols are used in program diagrams: / : Fade in \ : Fade out _ : Tube turned fully off.
  • Page 15 Example 5 The rainbow effect is achieved by selecting, red, green, blue and DIP-switch 7 is set to ON = crossfade@50%. red: /\+/\+/\+/\+/\+/\+/\+/\+/\+ green: +/\+/\+/\+/\+/\+/\+/\+/\+/\ blue: \+/\+/\+/\+/\+/\+/\+/\+/\+/ Scene: 012012012012012012012012012...
  • Page 16: Dmx Operation

    C o n n e c t i n g a D M X c o n t r o l d e v i c e Connect a data cable from the Cyclo 04 DMX to the control device’s data output.
  • Page 17: Control Address Selection

    C o n t r o l a d d r e s s s e l e c t i o n The Cyclo 04 DMX requires 4 DMX control channels. The DMX address, also known as the start channel, is the first control channel used. It is a logical address to which control instructions are sent.
  • Page 18 95 127 159 191 223 255 287 319 351 383 415 447 479 511 Table 2: DIP switch address settings 2 3 4 5 2 3 4 5 2 3 4 5 2 3 4 5 Channel 2 Channel 14 Channel 46 Channel 100 Address Setting Examples Cyclo 04 DMX user manual...
  • Page 19: Intensity Control

    I N T E N S I T Y C O N T R O L The intensity of the individual colors can be set from minimum to maximum on channels 1 to 4. Cyclo 04 DMX user manual...
  • Page 20: Dmx Protocol

    Intensity 1 100% 253-255 Intensity 100% Green intensity Tube off → 3-252 1 - 99 Intensity 1 100% 253-255 Intensity 100% Blue intensity Tube off → 3-252 1 - 99 Intensity 1 100% 253-255 Intensity 100% Cyclo 04 DMX user manual...
  • Page 21: Specifications - Cyclo Dmx

    Cyclo 04 DMX ........
  • Page 22 CAT5 network cables - 5 m (16.4 ft) x 30 pieces..... . .P/N 91611045 CAT5 network cables - 10 m (32.8 ft) x 15 pieces..... .P/N 91611045 Cyclo 04 DMX user manual...
  • Page 24 • Olof Palmes Allé 18 • 8200 Aarhus N • Denmark Tel: +45 8740 0000 • Fax +45 8740 0010...

Table of Contents