Section 7
6. Rotate the door hinge 160°-180°.
7. Hold the hinge, twist the door and slide the top pin into
the top hinge.
8. Screw the bottom hinge to the unit.
9. Check the door alignment. Check that it shuts and
seals. Adjust the bottom hinge if necessary.
Part Number GA_SM 08/18

Temperature Probe Resistance

Part 2195702
Temperature
Temperature
in °C
-20
-19
-18
-17
-16
-15
-2
-1
**0
1
2
3
4
5
20
21
22
23
24
25
** Resistance if probe is placed in an ice bath.
Component Check Procedures
5KΩ NTC Temperature Probe
Resistance (Ω)
in °F
Nominal
-4
48,560
-2.2
45,835
-0.4
43,275
1.4
40,870
3.2
38,610
5
36,490
28.4
18,100
30.2
17,190
32
16,330
33.8
15,520
35.6
14,755
37.4
14,030
39.2
13,345
41
12,700
68
6,245
69.8
5,970
71.6
5,710
73.4
5,460
75.2
5,225
77
5,000