7.3 Test in Initialize-1 and Initialize-2 menus

7.3.1 Test in Initialize-1 menu

1. System Test Results

The System Test Results show the results of the factory test described in page 7-6.
Normally, all the results are shown as "OK". The test results are stored in U13
(EEPROM) and not cleared even if "All Clear" is executed in "[MENU] -> Initialize1
-> All Clear".
2. Initialize1 -> View Nav Data
This setting allows monitoring of IEC61162 sentences inputted between #4 (RD-A) and
#5 (RD-B) of the INS port J402 (WAGO) on NX-7001.
Note:
Check that the baud rate (speed) of the inputted sentence meets the setting in
"[MENU] -> Service -> INS Input Speed". If the speeds do not match, the data
cannot be read correctly. As a result,
Initialize1
Menu
Delete All Msgs
All Clear
NAVTEX
Dem Mode
System
System Test Results
Display
View Nav Data
Service
ZCZC Chaeck
Initialize1
00 Msg Priority
Initialize2
Print Order
Available Rcv Station List
Adjust Rx Unit
Rx Test
is displayed.
Off
On
00>B1>B2
View nav data ?
Old -> New
Yes No
7-12
7.3 Test in Initialize-1 and Initialize-2 menus
VIEW NAV DATA
$GPZDA, 181052,25,08,2005,0
PGLL ,3444.974,N,13454.969
GLL ,3444.974,N,13454.969,E
[ENT] CLEAR
[MENU] RETURN TO MENU
Note;
Every time the [ENT] key is pressed,
the screen is updated.
I
L1
$G
$GPR