Overload Limiter; Override Of The Bottom Obstruction Detection Device - Avanti SHARK L AECO Original Instructions Manual

Table of Contents

Advertisement

7.6 Overload limiter

a) In case of an overload, the lift's upward travel
should be blocked, and a buzzer should sound in
the connection cabinet.
DANGER!
STOP
Attempting to go up in an
overloaded lift is prohibited!
b) Remove enough of the load to make the buzzer
!
stop and enable upward travel.
WARNING!
On entering and starting the lift, the buzzer
may sound briefly. This is due to temporary
load peaks occurring as the lift takes off.
The control box is designed not to activate the buzzer
or stop the lift because of peak loads caused by the
cabin swinging.
If problem persists have a certified technician adjust
the overload limiter (See "Regulation of overload
limiter" Appendix A).
7.7 Override of the bottom obstruction
detection device
For maintenance tasks only, it is possible to override
the bottom obstruction detection device by means of a
key on the cabin control box.
a) Descend the service lift until the the bottom
obstruction detection device reaches the floor.
b) Turn the override key of the cabin control box
(fig. 5 section 5.6.3) clockwise and hold.
c) Press and hold the DOWN button until the service
lift feet rest on the floor.
AT00016288 Shark L AECO EN update.indd 21
User's Manual
21
11/14/2018 4:02:46 PM

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents