Avanti DOLPHIN A-V164 Original Instructions Manual

Service lift
Hide thumbs Also See for DOLPHIN A-V164:

Advertisement

Original instructions
AVANTI SERVICE LIFT
User's Manual
Model Service Lift DOLPHIN A-V164
AT00014348_Dolphin A-V164_User´s Manual E01R05.indd 1
10/24/2018 12:24:48 PM

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the DOLPHIN A-V164 and is the answer not in the manual?

Questions and answers

Summary of Contents for Avanti DOLPHIN A-V164

  • Page 1 Original instructions AVANTI SERVICE LIFT User’s Manual Model Service Lift DOLPHIN A-V164 AT00014348_Dolphin A-V164_User´s Manual E01R05.indd 1 10/24/2018 12:24:48 PM...
  • Page 2 Certificate of Dolphin A-V164 AT00014348_Dolphin A-V164_User´s Manual E01R05.indd 2 10/24/2018 12:24:48 PM...
  • Page 3: At00014348_Dolphin A-V164_User´s Manual E01R05.Indd

    Avanti Wind Systems Limited P: +44 0 1254 399923 Avanti Wind Systems, Inc P: +1 (262) 641 9101 India Avanti Wind Systems India (P) Ltd P: +91 95 00 173 492 Brazil Avanti Brasil Sistema Eólicos LTDA P: +55 85 9 9955-0090 Manufactured Under Process Patent NO.8,499,896.
  • Page 4: Table Of Contents

    3.14.1 Fences for Dolphin A-V164........
  • Page 5: Limited Warranty

    AVANTI. IF, PURSUANT TO ANY APPLICABLE of the Product. The sole and exclusive remedy LAW, TO THE EXTENT AN IMPLIED WARRAN- and the entire liability of Avanti under this TY CANNOT BE EXCLUDED AS PROVIDED IN limited warranty, shall be, at the option of...
  • Page 6: Introduction

    Additional copies are available from the manufacturer upon request. This manual, including, but not limited to, measurements, procedures, components, descriptions, instruc- tions, recommendations and requirements, is subject to change without prior notice. Please check Avanti website/manuals for the latest revisions of the manuals.
  • Page 7: Cautions

    2.4 Terms and definitions Terms Definitions Person who has gone through the relevant training associated with the scheduled task from Avanti Certified technician or from a certified trainer and is in possession of a valid (non expired) certificate for the task.
  • Page 8: Description

    The service lift shall not be used outdoor or in potentially explosive atmospheres. The service lift is not designed to carry a person on its top. Unless otherwise agreed with Avanti, the wind turbine manufacturer is responsible of integrating the service lift and ensuring compliance with the...
  • Page 9: Dimensions

    Dimensions 66 0 75 5 66 0 66 0 75 5 75 5 1150 1150 1150 User’s Manual AT00014348_Dolphin A-V164_User´s Manual E01R05.indd 9 10/24/2018 12:24:56 PM...
  • Page 10: Components

    23. Warning light (2x) (Top and base) 12. External anchor point (1x) STOP The external anchor point must only be used for evacuation / rescue operation. AVANTI Service Lift for Wind Turbines AT00014348_Dolphin A-V164_User´s Manual E01R05.indd 10 10/24/2018 12:24:57 PM...
  • Page 11: Traction System

    Unit weight Service Lift Hoist Power capacity speed current wire rope Ø approx. Version Traction system type m/min Dolphin A-V164 M508/400V 50Hz M508/690V 50Hz Dolphin A-V164 Dolphin A-V164 M508/400V 60Hz 21.6 M508/690V 60Hz Dolphin A-V164 21.6 3.8 Fall arrest device Triggering...
  • Page 12: Main Control Box

    8. ASL light (red). Note: An interlock system (trapped key or guard lock- ing) is mandatory for the CE versions if platform fences are equipped with doors. AVANTI Service Lift for Wind Turbines AT00014348_Dolphin A-V164_User´s Manual E01R05.indd 12 10/24/2018 12:24:58 PM...
  • Page 13: Bottom Platform Control Box

    It must be set to OFF before starting an electrical generator. 3.14.1 Fences for Dolphin A-V164 3.12.1 Send and call configuration The platform fences shall conform to EN 14122-3. The following types of fences are possible as long as the following points are fulfilled: 1.
  • Page 14: Trapped Key System

    The door is unlocked when the service lift is at the platform with the lift detection switch activated. The green light is ON when the door is closed. AVANTI Service Lift for Wind Turbines AT00014348_Dolphin A-V164_User´s Manual E01R05.indd 14 10/24/2018 12:24:58 PM...
  • Page 15: Service Lift Door

    3.15 Service lift door 3.15.1 Full sliding door Main access to the cabin is done through the full It is possible to manually release guard sliding door installed on the front. The full sliding locking system in order to open main door door opening dimensions are 2100 x 570 mm.
  • Page 16: Emergency Top Limit Switch

    The top obstruction device switch stops ascent if the service lift: • encounters an obstacle • touches the top limit device Descent will be possible, for instance to remove the obstacle. obstruction device AVANTI Service Lift for Wind Turbines AT00014348_Dolphin A-V164_User´s Manual E01R05.indd 16 10/24/2018 12:25:01 PM...
  • Page 17: Manual Descent System

    3.19 Manual descent system - A foldable step is provided for access to the fall arrest device levers. The user must observe all safety The service lift is provided with a lever allowing precautions and check that the lift doors are closed manual release of the electromagnetic motor brake.
  • Page 18: Overload Limiter

    The light is on when the lift is powered, and it is also battery packed in order to illuminate the inside of the cabin in case of a power failure (once charged). AVANTI Service Lift for Wind Turbines AT00014348_Dolphin A-V164_User´s Manual E01R05.indd 18 10/24/2018 12:25:01 PM...
  • Page 19: Instructions For Use

    4. Instructions for use 4.1 Daily inspection Cabin control from outside of the cabin-Auto- Travel zone: matic: Ensure that there are no obstacles in the travel zone The automatic mode function is only available from which may obstruct the travel of the service lift. the control buttons outside of the cabin and shall be checked as follows (one technician inside the Service lift:...
  • Page 20: Bottom Platform

    In case of power failure and the fall arrest device is locked with the safety wire rope under tension evacuate the lift according to the evacuation procedure. AVANTI Service Lift for Wind Turbines AT00014348_Dolphin A-V164_User´s Manual E01R05.indd 20 10/24/2018 12:25:02 PM...
  • Page 21: Troubleshooting

    4.9 Troubleshooting 1. All tests and repairs to the electronic compo- 2. Repairs to the traction hoist, the fall arrest nents should be performed by certified device and to the system’s supporting compo- technicians only! The wiring diagram is nents should be performed by certified placed in the power cabinet.
  • Page 22 C1 Wire ropes are dirty. If possible, immediately replace the traction Motor hums loudly hoist and return it for test/repair at AVANTI. or wire ropes squeak, but the lift Further use of lift may can go both up and...
  • Page 23: Out Of Service

    Breakdown Cause Solution D3 Fault in down controller circuit Insert brake lever into the traction hoist Service lift will and lower lift manually. go up but not Test, and if necessary have connec- down! tions, wiring, and relays repaired. D4 Bottom stop switches: a) Test the bottom stop switches a) One or both of the bottom stop connection/function.
  • Page 24: Appendix A: Inspection Log Sheet

    - User must immediately bring the cabin down and test. park it at the bottom landing platform floor. - Lock Out the installation from use and contact Avanti 1. Test Preparation for further approach! The cabin (with 1 person inside) is ascended with a...
  • Page 25: Rønnevangs Allé

    P: +49 (0) 41 21-7 88 85 – 0 · F: +49 (0) 41 21- 7 88 85-20 Spain Avanti Wind Systems SL · Poligono Industrial Centrovia Calle Los Angeles No 88 nave 1 · 50198 La Muela P: +34 976 149524 · F: +34 976 149508...

Table of Contents

Save PDF