AVANTI. IF, PURSUANT TO ANY APPLICABLE of the Product. The sole and exclusive remedy LAW, TO THE EXTENT AN IMPLIED WARRAN- and the entire liability of Avanti under this TY CANNOT BE EXCLUDED AS PROVIDED IN limited warranty, shall be, at the option of...
Additional copies are available from the manufacturer upon request. This manual, including, but not limited to, measurements, procedures, components, descriptions, instruc- tions, recommendations and requirements, is subject to change without prior notice. Please check Avanti website/manuals for the latest revisions of the manuals.
2.4 Terms and definitions Terms Definitions Person who has gone through the relevant training associated with the scheduled task from Avanti Certified technician or from a certified trainer and is in possession of a valid (non expired) certificate for the task.
The service lift shall not be used outdoor or in potentially explosive atmospheres. The service lift is not designed to carry a person on its top. Unless otherwise agreed with Avanti, the wind turbine manufacturer is responsible of integrating the service lift and ensuring compliance with the...
23. Warning light (2x) (Top and base) 12. External anchor point (1x) STOP The external anchor point must only be used for evacuation / rescue operation. AVANTI Service Lift for Wind Turbines AT00014348_Dolphin A-V164_User´s Manual E01R05.indd 10 10/24/2018 12:24:57 PM...
8. ASL light (red). Note: An interlock system (trapped key or guard lock- ing) is mandatory for the CE versions if platform fences are equipped with doors. AVANTI Service Lift for Wind Turbines AT00014348_Dolphin A-V164_User´s Manual E01R05.indd 12 10/24/2018 12:24:58 PM...
It must be set to OFF before starting an electrical generator. 3.14.1 Fences for Dolphin A-V164 3.12.1 Send and call configuration The platform fences shall conform to EN 14122-3. The following types of fences are possible as long as the following points are fulfilled: 1.
The door is unlocked when the service lift is at the platform with the lift detection switch activated. The green light is ON when the door is closed. AVANTI Service Lift for Wind Turbines AT00014348_Dolphin A-V164_User´s Manual E01R05.indd 14 10/24/2018 12:24:58 PM...
3.15 Service lift door 3.15.1 Full sliding door Main access to the cabin is done through the full It is possible to manually release guard sliding door installed on the front. The full sliding locking system in order to open main door door opening dimensions are 2100 x 570 mm.
The top obstruction device switch stops ascent if the service lift: • encounters an obstacle • touches the top limit device Descent will be possible, for instance to remove the obstacle. obstruction device AVANTI Service Lift for Wind Turbines AT00014348_Dolphin A-V164_User´s Manual E01R05.indd 16 10/24/2018 12:25:01 PM...
3.19 Manual descent system - A foldable step is provided for access to the fall arrest device levers. The user must observe all safety The service lift is provided with a lever allowing precautions and check that the lift doors are closed manual release of the electromagnetic motor brake.
The light is on when the lift is powered, and it is also battery packed in order to illuminate the inside of the cabin in case of a power failure (once charged). AVANTI Service Lift for Wind Turbines AT00014348_Dolphin A-V164_User´s Manual E01R05.indd 18 10/24/2018 12:25:01 PM...
4. Instructions for use 4.1 Daily inspection Cabin control from outside of the cabin-Auto- Travel zone: matic: Ensure that there are no obstacles in the travel zone The automatic mode function is only available from which may obstruct the travel of the service lift. the control buttons outside of the cabin and shall be checked as follows (one technician inside the Service lift:...
In case of power failure and the fall arrest device is locked with the safety wire rope under tension evacuate the lift according to the evacuation procedure. AVANTI Service Lift for Wind Turbines AT00014348_Dolphin A-V164_User´s Manual E01R05.indd 20 10/24/2018 12:25:02 PM...
4.9 Troubleshooting 1. All tests and repairs to the electronic compo- 2. Repairs to the traction hoist, the fall arrest nents should be performed by certified device and to the system’s supporting compo- technicians only! The wiring diagram is nents should be performed by certified placed in the power cabinet.
Page 22
C1 Wire ropes are dirty. If possible, immediately replace the traction Motor hums loudly hoist and return it for test/repair at AVANTI. or wire ropes squeak, but the lift Further use of lift may can go both up and...
Breakdown Cause Solution D3 Fault in down controller circuit Insert brake lever into the traction hoist Service lift will and lower lift manually. go up but not Test, and if necessary have connec- down! tions, wiring, and relays repaired. D4 Bottom stop switches: a) Test the bottom stop switches a) One or both of the bottom stop connection/function.
- User must immediately bring the cabin down and test. park it at the bottom landing platform floor. - Lock Out the installation from use and contact Avanti 1. Test Preparation for further approach! The cabin (with 1 person inside) is ascended with a...