AVANTI SERVICE LIFT
Date of publication:
User's manual
2nd Edition: July 2017
Revision 4: 12/02/2019
Model Service Lift SWP XL 02 CE
This manual covers products with Serial numbers from A4-XL0001
AT00010432 SWP XL02 Lift User's Manual CE EN E02 R04 – Language: ENGLISH
AT00010432 SWP XL02 User's Manual CE-AECO EN E02R04.indd 1
12/02/2019 10:09:53

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the SWP XL 02 CE and is the answer not in the manual?

Questions and answers

Summary of Contents for Avanti SWP XL 02 CE

  • Page 1 User’s manual 2nd Edition: July 2017 Revision 4: 12/02/2019 Model Service Lift SWP XL 02 CE This manual covers products with Serial numbers from A4-XL0001 AT00010432 SWP XL02 Lift User’s Manual CE EN E02 R04 – Language: ENGLISH AT00010432 SWP XL02 User’s Manual CE-AECO EN E02R04.indd 1...
  • Page 2 CE certificate for SWP XL: AT00010432 SWP XL02 User’s Manual CE-AECO EN E02R04.indd 2 12/02/2019 10:09:53...
  • Page 3 Date of publication: 2nd Edition: July 2017 Revision 4: 12/02/2019 Manufacturer: Avanti Wind Systems Technology, S.L. Calle Ángeles (Los), Num. 88 Pol. Industrial Centrovía 50198 Muela (La) - (Zaragoza)- Spain P: +34 976 149524 F: +34 976 149508 E: info@avanti-online.com I: www.avanti-online.com...
  • Page 4: Table Of Contents

    APPENDIX A: DAILY INSPECTION LOG ..........23 AVANTI Service Lift for Wind Turbines AT00010432 SWP XL02 User’s Manual CE-AECO EN E02R04.indd 4...
  • Page 5 Section 2.1 re-worded. Added description of shock absorber in fall arrest device (section 4.10). Added description of manual descent hour counter in main control box. Updated section 2.4 Terms and definitions. Other minor changes. 02.02 Changed Avanti logos 02.03a Editorial updates.
  • Page 6: Limited Warranty

    HEREBY EXCLUDED TO THE MAXIMUM of the Product. The sole and exclusive remedy EXTENT PERMITTED BY APPLICABLE LAW and the entire liability of Avanti under this AND ARE EXPRESSLY DISCLAIMED BY limited warranty, shall be, at the option of AVANTI. IF, PURSUANT TO ANY APPLICABLE...
  • Page 7: Introduction

    2. Introduction 2.1 Observations Only trained people may use this lift. This manual must be available to staff at all times during installation, maintenance and operation. Additional copies are available from the manufacturer upon request. All measurements are indicative only and subject to change without notice.
  • Page 8: Cautions

    Person who has gone through the relevant training associated with the scheduled task Certified technician from Avanti or from a certified trainer and is in possession of a valid (non expired) certificate for the task. Person who has gone through the relevant training associated with the Avanti service lift User use and daily inspection and is in possession of a valid (non expired) certificate for the task.
  • Page 9: Description

    3. Description 3.1 Purpose 3.3 Exclusions The service lift described in this User’s Manual The lift is not designed for use serves the following purposes: - in silos, - Transportation of staff and material inside wind - at drilling sites, turbine systems, lattice towers for wind turbines, - as a permanently installed facade lift, and telecommunication towers.
  • Page 10: Dimensions

    3.5 Dimensions 3.5.1 Dimensions of SWP XL AVANTI Service Lift for Wind Turbines AT00010432 SWP XL02 User’s Manual CE-AECO EN E02R04.indd 10 12/02/2019 10:09:57...
  • Page 11: Components

    3.6 Components 3.6.1 Components of SWP XL Cabin Door Traction and safety wire ropes Guiding wire rope Wire rope guides Bottom obstruction device Top obstruction device Traveling cable pulley User’s manual AT00010432 SWP XL02 User’s Manual CE-AECO EN E02R04.indd 11 12/02/2019 10:09:57...
  • Page 12: Traction System

    2 t shackle Guiding wire rope 12 mm 55 kN 2 t shackle 3.6.5 Main control box of SWP XL 1 Manual descent hour counter AVANTI Service Lift for Wind Turbines AT00010432 SWP XL02 User’s Manual CE-AECO EN E02R04.indd 12 12/02/2019 10:09:57...
  • Page 13: Service-Lift Operating Panel

    3.6.6 Service-lift operating panel 1 Emergency stop button 6 Error display 2 UP button 7 INT/OFF/EXT selector Error Display: See section 3 Platform indicator (green light) 8 Bottom obstruction override 4.12 Troubleshooting 4 DOWN button switch 5 Reset button / Ready lamp 9 Hour counter 3.6.7 Platform operating panels Top and intermediate platforms...
  • Page 14: Main Switch

    During manual descent, the door of the lift shall be kept closed. Do not extend body parts STOP outside the cabin during travel. AVANTI Service Lift for Wind Turbines AT00010432 SWP XL02 User’s Manual CE-AECO EN E02R04.indd 14 12/02/2019 10:09:58...
  • Page 15: Obstruction Switches

    3.6.17 Obstruction switches 3.6.19 Wire inspection cover 3.6.17.1 Top obstruction switch Maintenance cover allows safe and fast inspection At the top of the cabin a top obstruction switch will of traction and safety wire ropes from inside the stop upward travel when activated and the ‘Top cabin while travelling.
  • Page 16: Instructions For Use

    EMERGENCY STOP button and press the reset button. The result of the test shall be recorded in the “Daily inspection log sheet” (appendix A). AVANTI Service Lift for Wind Turbines AT00010432 SWP XL02 User’s Manual CE-AECO EN E02R04.indd 16 12/02/2019 10:09:58...
  • Page 17 e) Operation selector INT/OFF/EXT: 4.1.3.2 Cabin operation from outside of the cabin – Automatic Send function Turn the selector to OFF – it shall not be possible The automatic mode function is only available from to move the lift upwards or downwards. The result the control buttons outside of the cabin and shall of the test shall be recorded in the “Daily be checked as follows (one technician inside the...
  • Page 18: Prohibited Uses

    The operation selector shall be INT nel from AVANTI or competent persons certified c) Press the reset button by AVANTI are allowed to perform service on the d) To go up or down, push and hold the Up or machine.
  • Page 19: Operation From Platforms (Send And Call Configuration)

    4.7 Operation from platforms (send 4.5, 4.6, 4.7: When actuating UP or DOWN and call configuration) buttons, response of cabin is delayed for 5 Transportation of people is forbidden if the seconds while the warning lights are flashing, operation is controlled from the platforms. in order to warn personnel in the surroundings that cabin is going to move.
  • Page 20: Overload Limiter

    If the error display light is still ON and the lift blocked, have an AVANTI expert adjust the Shock absorber overload limiter. 4.9 Manual descent If a power failure or an operation fault etc.
  • Page 21: After Use Instructions

    2. Push the Reset button. The service lift 3. If error light is still ON, call AVANTI or certified technician. will neither go up nor down! 1. Descent electrically by pushing and holding the DOWN button until the top obstruction switch is released, and error light is turned off.
  • Page 22: Out Of Service

    The service lift 2. Push the Reset button. will neither go up nor 3. If error light is still ON, call AVANTI or certified technician. down! 1. Close properly the door, and check the functionality of the internal manual release lever and the external release button of the door interlock until error light is turned off.
  • Page 23: Appendix A: Daily Inspection Log

    I: www.avanti-online.com E: info@avanti-online.com AT00010432 SWP XL02 User’s Manual CE-AECO EN E02R04.indd 32 12/02/2019 10:10:00...