Hussmann Freedom Line series Installation & Operation Manual page 89

Meat, delicatessen, dairy and produce merchandisers compressor ready
Hide thumbs Also See for Freedom Line series:
Table of Contents

Advertisement

AE8-1376 R5
Label
LS
Minimum set point (PSIG)
US
Maximum set point (PSIG)
ono
Minimum time between two compressor starts (minutes)
nFA
Number of fans on during probe fault
Unt
Measurement unit for pressure: PSIG, bar, kPA
CF
Measurement unit for temperature
on
Bump Start Compressor on time (seconds)
off
Bump Start Compressor off time (seconds)
nUb
Number of cycles during bump start
bEn
Compressor stop time for next bump start (hours)
doF
DLT alarm temperature to stop compressor (°F)
don
DLT temperature for compressor restart (°F)
ALd
DLT stop compressor delay (seconds)
Minimum time of compressor off with dLL alarm (minutes)
dlF
AU2
Cut-in for Condenser Temperature/Pressure alarm (°F)
AH2
Cut-out for high Condenser Temperature/Pressure alarm (°F)
Ad2
High condenser temperature alarm delay (minutes)
Minimum off time after a High-Pressure Trip (minutes)
HPF
P1i
Start scale for probe 1 (PSIG)
P1E
End scale for probe 1 (PSIG)
P1d
P1 alarm display delay, with P1C=0-5V (min)
P2P
Probe 2 presence
Probe 2 configuration
P2C
P2i
Start scale for probe 2 (PSIG)
P2E
End scale for probe 2 (PSIG)
Probe 3 configuration
P3C
High condenser temperature alarm with compressor off
Ab2
AUX 1 configuration
oA1
AUX 2 configuration
oA2
© 2015 Emerson Climate Technologies, Inc.
Application Engineering
B
U
L
Table 5 – Factory Set Parameters
Description
Factory Set Definitions
7-11
L
E
T
I
N
May 2016
Default
Range
-7 or 5
-7 - US
135
LS - 135
0
0 - 15
2
0 - 2
PSI
PSI, bAr, HPA
F
C or F
2
1 - 15
5
1 - 15
3
1 - 15
4.0
1.0 - 23.5
220
don - 302
170
-58 - doF
0-5
0 - 255
0
0 - 15
150
AH2 - 230
140
-40 - AU2
0
0 - 255
5
0 - 15
-15
-15 to P1E
135
P1i to 999
0
0 -100
YES, NO
NTC, 0-5
-15
-15 to P2E
485
P2i to 999
Nu, DLT, CPA
Yes, No
Fan, Fn2, Alr
Fan, Fn2, Alr