Device Identification/Identcode - ProMinent S2Ba Operating Instructions Manual

Sigma/ 2 metering pump
Table of Contents

Advertisement

Dulcodes UV-Desinfektionsanlage
Dulcodes UV-Desinfektionsanlage
Identcode ordering system
Please enter the identcode on the device label into the grey box below.
S 2 B a
S i g m a B a s i c Ty p e ( S 2 B a )
HM
Main drive, diaphragm
16050 16 bar; 50 l/h
16090 16 bar; 90 l/h
16130 16 bar; 130 l/h
12050* 10 bar; 48 l/h
12090* 10 bar; 86 l/h
12030* 10 bar; 125 l/h
07120
07220
04350
S2Ba
___
___
®
Viton
is a registered trademark of DuPont Dow Elastomers.
®
ProMinent
®
ProMinent
Pump type: (figures 1+2 = back pressure [bar], figures 3-5 = feed rate [l/h])
7 bar; 120 l/h
7 bar; 220 l/h
4 bar; 350 l/h
* for SST versions, max. 12 bar
Liquid end materials:
PV
PVDF
SS
Stainless steel
Seal material:
T
PTFE seal
Diaphragm:
0
Standard diaphragm, PTFE version
1
Double diaphragm with diaphragm rupture indicator (retro fit possible)
Liquid end version:
0
No spring
1
With 2 valve springs, Hastelloy C, 0.1 bar
4
With pressure relief valve, Viton
5
With pressure relief valve, Viton
0
1
2
3
4
7
8
___
___
___
___
___
®
seal, no valve spring
®
seal, and valve spring
Hydraulic connection:
Standard threaded connector (according to technical data)
Union nut and PVC insert
Union nut and PP insert
Union nut and PVDF insert
Union nut and stainless steel insert
Union nut and PVDF hose nozzle
Union nut and stainless steel hose nozzle
Version:
®
0
With ProMinent
logo (standard)
1
Without ProMinent
®
logo
Electrical power supply:
S
3 ph, 230 V/400 V 50/60 Hz, 0.18 kW
M
1 ph, AC, 230 V/50/60 Hz, 0.18 kW
N
1 ph, AC 115 V 60 Hz, 0.18 kW
L
3 ph, 230 V/400 V, 50 Hz, (EExe, EExde)
P
3 ph, 230 V/400 V, 60 Hz, (EExe, EExde)
R
3 ph, variable speed motor, 230/400 V, 0.37 kW
V
Variable speed motor with integrated speed control 1 pH,
230 V, 50/60 Hz
Z
1 ph, variable speed control set 1 ph, 230 V, 50/60 Hz
1
No motor, with B14 flange (Gr. 71 (DIN))
2
No motor, C 56 flange (NEMA)
3
No motor, B5 Gr. 63 (DIN)
4
No motor, B5, Gr. 70 (DIN)
Motor version:
0
IP 55 (standard)
1
Exe version (II 2G EExe II T3)
2
Exde version (II 2G EExde IIC T4)
A
ATEX type drive
Stroke sensor:
0
No stroke sensor (standard)
1
with stroke sensor (Hall sensor, no connection cable)
2
Pacing relay (reed relay)
3
Stroke sensor (Namur) intrinsically safe
0
1
2
3
4
5
6
___
___
___
___
___
Identcode ordering system
Stroke length adjustment:
Manual (standard)
With stroke positioning motor, 230 V/50/60 Hz
With stroke positioning motor, 115 V/50/60 Hz
With stroke control motor,
0...20 mA 230 V/50/60 Hz
With stroke control motor
4...20 mA 230 V/50/60 Hz
With stroke control motor
0...20 mA 115 V/50/60 Hz
With stroke control motor
4...20 mA 115 V/50/60 Hz
Page 9

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

S2ca

Table of Contents