General Operation
PWSRTA Twin Alternating Series Softeners

User Displays

When the system is operating, one of five displays may be shown. Pressing NEXT will alternate
between the displays shown below.
User 1
Typical user display. Shows volume remaining to regeneration. This screen will not be viewed if the
control is set for time-clock operation.
User 2
Displays number of days to next regeneration.
User 3
Flow Rate.
Displays present flow rate.
Not viewed (along with SOFTENING or FILTERING Icon) if ALT A or ALT b is set in CONFIGURATION 4
and the valve is currently in Standby. When 1.0 is set in CONFIGURATION 1, the display will indicate
the tank currently in Service ("A" or "b") in the leftmost digit.
User 4
Displays total volume in gallons since last reset. If a meter is not used this display will be shown but 0
will be displayed.
PRESS  FOR 3 SECONDS TO RESET TO 0.
User 5
Shows current time.
Setting Time of Day
Push NEXT until time of day screen is displayed. Press and hold  until SET TIME is displayed and the
hour flashes once. Press  or  until the correct hour is displayed.
Then press NEXT. The minutes will flash. Press  or  until the correct minute is displayed.
Press NEXT to return to the User Displays. Time of day should only need to be set after power outages
lasting more than 8 hours, if the battery has been depleted and a power outage occurs, or when
daylight saving time begins or ends. If a power outage lasting more than 8 hours occurs, the time of
day will flash on and off which indicates the time of day should be reset. If a power outage lasts less
than 8 hours and the time of day flashes on and off, the time of day should be reset and the battery
replaced.