PWSRTA Twin Alternating Series Softeners
Setting Options Table
Filters should only use shaded options
Day
Override
Reserve capacity automatically estimated.
oFF
Regeneration occurs when volume capacity falls below the reserve capacity at the
next Regen Set Time.
Reserve capacity automatically estimated.
Regeneration occurs at the next Regen Set Time when volume capacity falls below
Any number
the reserve capacity or the specified number of days between regenerations is
reached.
Reserve capacity not automatically estimated.
oFF
Regeneration occurs at the next Regen Set Time when volume
capacity reaches 0.
Reserve capacity not automatically estimated.
Any number
Regeneration occurs at the next Regen Set Time when the specified number of
days between regenerations is reached.
Reserve capacity not automatically estimated.
Regeneration occurs at the next Regen Set Time when volume
Any number
capacity reaches 0 or the specified number of days between regenerations is
reached.
Reserve capacity NOT automatically estimated.
Regeneration occurs immediately when volume capacity reaches 0. Time of
oFF
regeneration will not be allowed to be set because regeneration will always occur
when volume capacity reaches 0.
Reserve capacity NOT automatically estimated.
Regeneration occurs immediately when volume capacity reaches 0. Time of
oFF
regeneration will not be allowed to be set because regeneration will always occur
when volume capacity reaches 0.
Reserve capacity automatically estimated.
Regeneration occurs when volume capacity falls below the reserve capacity at the
oFF
next Regen Set Time or regeneration occurs after 10 minutes of no water usage
when volume capacity reaches 0.
Reserve capacity automatically estimated.
Regeneration occurs at the next Regen Set Time when volume capacity falls below
Any number
the reserve capacity or the specified number of days between regenerations is
reached or regeneration occurs after 10 minutes of no water usage when volume
capacity reaches 0.
Reserve capacity not automatically estimated.
Regeneration occurs at the next Regen Set Time when the specified number of
Any number
days between regenerations is reached or regeneration occurs after 10 minutes of
no water usage when volume capacity reaches 0.