PWSRTA Twin Alternating Series Softeners

Diagnostics

Step 1D -
Press  and  simultaneously for 5 seconds and release. If screen in Step 2D does not
appear the lock on the valve is activated. To unlock press , NEXT, , REGEN in sequence, then
press  and  simultaneously for 5 seconds and release.
Step 2D –
Software Version. Press NEXT to go to Step 3D. Press REGEN to exit Diagnostics.
Step 3D –
Volume, total used since start-up: This display shows the total gallons treated since startup.
This display will equal zero if a water meter is not installed. Press the NEXT button to go to Step 4D.
Press REGEN to return to previous step.
Step 4D –
Days, total since start-up: This display shows the total days since startup. Press the NEXT
button to go to Step 5D. Press REGEN to return to previous step.
Step 5D –
Regenerations, total number since start-up: This display shows the total number of regenera-
tions that have occurred since startup. Press the NEXT button to go to Step 6D. Press REGEN to return
to previous step.
Step 6D – Error Log: This display shows a history of the last 10 errors generated by the control
during operation. Press  or  to view each recorded error.
Press NEXT to go to Step 7D. Press REGEN to return to previous step.
Step 7D –
Days, since last regeneration: This display shows the days since the last regeneration
occurred. Press NEXT to go to Step 8D. Press REGEN to return to previous step.
Step 8D –
Volume, since last regeneration: This display shows the volume of water that has been
treated since the last regeneration. This display will equal zero when a water meter is not installed. Press
NEXT to go to Step 9D. Press REGEN to return to previous step.