IOM-WQ-PWS20_PWS20-2_PWS20-P Installation, Operation and Maintenance 2" Commercial Water Softeners Series: PWS20, PWS20-2 & PWS20-P PWS20 Simplex Systems PWS20-2 Duplex Alternating Systems PWS20-P Duplex, Triplex and Quadplex Progressive Systems...
Page 2
Congratulations on your purchase of this Watts commercial water softening solution. ® You have made a great choice to protect your plumbing system against the damaging effects of hard water. This system has been engineered for trouble free operation and produced using top quality components. Simple programming, corrosion resistant mineral tank(s) and an easy to service design ensures this system will be durable and easy to maintain.
If you are unsure about installing your Watts water softener • To disconnect power, unplug the AC adapter from its power contact a Watts representative or consult a professional water source.
Project Data Sheet Job Details Job Number: _____________________________________________ Model Number: __________________________________________ Water Hardness: _______________ppm or gpg Capacity Per Unit: Mineral Tank Size: _____________Diameter: _____________ Height: Salt Setting per Regeneration: Regenerant Flow:_____________Upflow _____________ Downflow 1. Meter Size: A. 3/4" Paddle Wheel B.
System Specifications Dimensions - Weights PWS20-2 PWS20 & PWS20-P SIDE SIDE FRONT FRONT NOTICE Dimensional data is for a single mineral tank system ONLY. PWS20-P models are composed of multiple PWS20 systems. See Space Required in table below. Series PWS20 & PWS20-P MODEL NO.
Page 7
System Specifications Ordering Information for 2" Simplex and Duplex Alternating Softeners SPACE REQUIRED WEIGHT ORDERING CODES DESCRIPTION MODEL NO. D X W X H PWS20131D11 7100031 3 Cubic Foot 2" Simplex Softener with Flow Meter 18" x 39" x 87" PWS20131E11 7100032 4 Cubic Foot 2"...
Hardness (maximum) ... Depends on customer’s series number. If any components are missing or damaged acceptable hardness contact your Watts representative. If they can not be reached leakage level contact Watts customer service at 1-800-224-1299.
O-ring applica- ing this step, seat the top of the distributor tube inside the tions. Watts recommends Ordering Code #7300948 Silicone Lubricant. The use of other types of lubricants may attack distributor port located on the bottom of the control valve the control’s plastic or rubber components.
8*. Install an inlet water sample port in the supply line and close it. 3. Check for leaks and repair as needed. 9*. If risk of vacuum exists, install Watts # 0556031 vacuum 4. Plug the power cord of the control valve into an electrical relief valve in the supply line to protect the system against outlet to energize system.
& install vacuum relief valve Watts ordering code # 0556031 on inlet line. Drain and Brine Connection Detail 9. Brine tank dimensions shown on table are factory selected for use with the specified system size.
Controller Electrical Connections Power Supply Connections Network / Communication Cables and Connections Installing the Power Supply: Note: Power Supply includes a harness with 2 black wires Use a shielded CAT5 Network/Communication cable. that connect to circuit board, see page 15. Connect the network/communication cable first before programming.
NXT2 Controller Programming and Operation Features This system uses the NXT2 controller which is capable of operating single or multi-tank systems. On-screen multilingual support: English, Francais, Deutsch, Italiano, Espanol, Nederlands, Portugues • Time of day super capacitor backup for 12-hour power loss •...
Controller Operation Setting the Time of Day Note: Set Time of Day on any unit and the rest of the units in the system will update the Time of Day automatically. 1. Press and hold the Up button for 2 seconds. The “Time” value is displayed.
Controller Features Remote Lock Regeneration Types The controller does not allow the unit/system to go into Softener/Filter Meter Delayed - When volume remaining Regeneration until the Regeneration Lockout Input signal to the reaches zero and the scheduled regeneration time is reached unit is cleared.
Page 20
Controller Features Push Settings System 8 (2 Units) Alternating Delayed The ability to transmit user settings from one unit to all other con- Immediate Transfer Delayed Regeneration One tank online sup- nected units. Select the desired Master Programming settings plying treated water, one tank in Standby. Only #1 control will on one unit then push the same settings to all other connected monitor its flow meter/sensor input.
Master Programming Mode Flow Chart Example: On: View settings without the ability to alter settings. Off: User has ability to alter settings. Before entering Master Programming, please contact your local professional water dealer. Example: English, Francais, Duetsch, Italiano, Espanol, Nederlandse, Portugues NOTE: Depending on current option settings, some values Example: cannot be viewed or set.
Master Programming Mode User Programming Mode Flow Chart - Cont’d Flow Chart Example: User Programming Mode Range: 0 - 23 Hours 59 Minutes 1. Press and hold the Down and Up buttons simultaneously for 3 seconds to enter the User Programming mode. 2.
Diagnostic Programming Mode Flow Chart Diagnostic Programming Mode Example: 1. Press and hold the Left button to enter Diagnostic Record of error events chronologically Programming mode. 2. To navigate, press the Extra Cycle button to advance to the next value. Press the Left button to retreat to the previous value. Example: 3.
Time of Day Programming Mode Flow Chart Setting the Time of Day NOTE: Set Time of Day on any unit and the rest of the units in the system will update the Time of Day automatically. 1. Press and hold the Up button for 2 seconds. The “Time” value is displayed.
NXT2 Programming Parameters and Ranges SYSTEM TYPE PROGRAMMING PARAMETER RANGES SOFTENER/ SOFTENER/ PROGRESSIVE TIME FILTER FILTER REGEN TYPE OF THE INTERLOCK SERIES ALTERNATING ALTERNATING ALTERNATING DEMAND METRIC CLOCK METERED METERED WEEK RECALL IMMEDIATE DELAYED Settings Review On, Off English Francais Deutsch Language Italiano...
Replacing the Media 15. Continue to siphon resin until it is completely evacuated from NOTICE the mineral tank. Gravel will clogged the siphon hose and, if Ion exchange resin may need to be replaced periodically it must be removed due to fouling, or to repair or replace a due to physical breakdown caused by chlorine/chloramine damaged distributor tube and screen, must be evacuated by disinfectants, or fouling caused by certain metals such as...
Replacement Parts - Major System Components MAJOR SYSTEM COMPONENTS ITEM NO. ORDERING CODES DESCRIPTION 68103837 K4018-NTH VALVE 2900/1650 120V HWBP FOR SIMPLEX MODELS W/ 16" & SMALLER MINERAL TANK 68103835 K4018-NT VLV 2900/1650 120V NHWBP FOR ALTERNATING & PROGRESSIVE MODELS W/ 16" & SMALLER MINERAL TANK 68103827 K4017-NTH VLV 2900/1710 120V HWBP FOR SIMPLEX MODELS W/ 18"...
Page 28
68100706 C1038 FIBERGLASS MINERAL TANK 36X72 ALMOND W/ 6" FLANGE TOP 7300100 A4000 SOFTENING RESIN MEDIA WATTS BRAND HIGH CAPACITY SAC NA FORM 1 CUBIC FOOT PER BAG 68100354 A7005A MEDIA GRAVEL #20 FLINT 0.625"X.125" 50 LBS PER BAG 7300102 A7006A MEDIA GRAVEL .25"X.125"...
NXT to NXT2 Conversion Kit NXT TO NXT2 CONVERSION KIT ITEM NO. PART NUMBER DESCRIPTION 68104778 K4562121-01 CONTROLLER ASSY CONV KIT NXT TO NXT2 W/ 24V US POWER SUPPLY...
Replacement Parts - 2900 Lower Powerhead 2900 LOWER POWERHEAD ITEM NO. PART NUMBER DESCRIPTION 68104635 K4560411-NT LOWER POWERHEAD F/ 2900S 24V NTXT2, NO COVER 68104574 K4560217-02 COVER FOR 2900 LOWER POWER HEAD ENVIRO...
Replacement Parts - 2900S Control Valve Body 2900S DOWNFLOW CONTROL VALVE BODY ASSEMBLY ITEM NO. ORDERING CODES DESCRIPTION VALVE BODY 2900S MACHINED, NPT U.S. TAP 7300795 K4561530 SEAL & SPACER KIT F/ 2900S UPPER 7300794 K4561540 PISTON ASSEMBLY DOWNFLOW F/ 2900S UPPER 7300798 K4560128 SEAL &...
Replacement Parts - 2" Stainless Steel Mech/Electronic Meter 2 INCH STAINLESS STEEL METER ASSY ITEM NO. PART NUMBER DESCRIPTION 7300855 K4561934-10 METER ASSEMBLY COMPLETE 2" STAINLESS STEEL MECH/ELEC 68104199 K4514716 METER DOME PLASTIC FOR 2" METER W/ O-RING MECH/ELEC...
Troubleshooting Problem Cause Correction Water conditioner Electrical service to unit has been Assure permanent electrical service (check circuit breaker, GFCI, fails to regenerate interrupted fuse, plug, pull chain, or switch) Controller is defective Replace controller Power failure Reset time of day Softener delivers By-pass valve is open Close by-pass valve...
Page 40
Push correct system settings in Master Settings System Type Mismatch not match on Network Microcontroller Error Calibration or manufacturing test was Contact your Watts representative not performed 100 Days Without Regen 100 Days have expired without a regeneration Trigger a manual regeneration...
Water Softener Flow Diagrams - Down Flow Brining 1 Service Position 4 Slow Rinse Position 5 Rapid Rinse Position 2 Backwash Position 3 Brine Position 6 Brine Tank Refill Position...
Page 42
Water Softener Flow Diagrams - Up Flow Brining 1 Service Position 4 Backwash Position 2 Brine Position 5 Rapid Rinse Position 3 Slow Rinse Position 6 Brine Tank Fill Position...
SO FAR AS IS CONSISTENT WITH APPLICABLE STATE LAW, ANY IMPLIED WARRANTIES THAT MAY NOT BE DISCLAIMED, INCLUDING THE IMPLIED WARRANTIES OF MERCHANTABILITY AND FITNESS FOR A PARTICULAR PURPOSE, ARE LIMITED IN DURATION TO ONE YEAR FROM THE DATE OF ORIGINAL SHIPMENT. USA: T: (800) 224-1299 • F: (978) 794-1848 • Watts.com/PureWater Canada: T: (888) 208-8927 • F: (905) 332-7068 • Watts.ca/PureWater Latin America: T: (52) 55-4122-0138 •...