Configuring the Control Valve for System Controller Operation:
Select "SYS" to link control valve to System Controller. For communication between control valve and
System Controller, a three-wire communication cable is required.
Selection requires that a connection to a Watts No Hard Water Bypass (V3070FF or V3070FM) be
made to the two-pin connector labeled MAV located on the printed circuit board for PWSRTA control
valves. For valve types PWSRTA15 and PWSRTA2, a connection from a Watts No Hard Water Bypass
(V3097/ BSPT or V3098/ BSPT) to the two pin connector labeled MAV located on the printed circuit
board is required.
Press NEXT to go to Step 6CS. Press REGEN to return to previous step.
Step 6CS
EXIT TO DISPLAY SCREENS
PWSRTA Twin Alternating Series Softeners
Step 6CS –
Fill Units: If set as a softener, if Step 2CS is set to 1.5, and FILL is part of the Regeneration
Cycle Sequence, FILL UNITS of MIN or LBS can be selected. Press
NEXT to exit OEM Configuration Setup. Press REGEN to return to previ-
ous step.
13