Watts PWSRTA Series Installation, Operation And Maintenance Manual page 22

Twin alternating series softeners
Table of Contents

Advertisement

Step 9D
Step 10D
Step 11D
Step 12D
Press and hold  and  buttons for 3 seconds while in Step 12D to
reset the MAV drive history in both the retracted and extended piston
rod position. To view the old MAV drive history data for retracted
and extended rod position press and hold REGEN and  while in
Step 12D. Press NEXT to advance display to the old MAV drive his-
tory.
Step 13D
EXIT DIAGNOSTICS
pressed to move backwards in the day series. This display does not appear if 1.0 is set in Step 2CS,
if ALT A or ALT B are selected in Step 5CS, or anytime the reserve capacity is not determined by the
control.
Press NEXT at any time to go to Step 10D. Press REGEN to return to previous step.
Press NEXT at any time to go to Step 11D. Press REGEN to return to previous step.
ago that the transfer occurred. The display alternates with the volume that was treated before the tank
transferred. Press NEXT at any time to go to Step 12D. Press REGEN to return to previous step.
the extended and retracted piston rod position. To view the old MAV drive history data see Step 12D.
Press NEXT at any time exit Diagnostics. Press REGEN to return to previous step.
Step 9D –
Volume, reserve capacity used for last 7 days: If the valve
is set up as a softener, a meter is installed, and Set Volume Capacity
is set to "Auto," this display shows day 0 (for today) and flashes the
reserve capacity. Pressing  will show day 1 (which would be yes-
terday) and flashes the reserve capacity used. Pressing  again will
show day 2 (the day before yesterday) and the reserve capacity. Keep
pressing  to show the capacity for days 3, 4, 5 and 6.  can be
Step 10D –
Volume, 63-day usage history: This display shows day
0 (for today) and flashes the volume of water treated today. Pressing
 will show day 1 (which would be yesterday) and flashes the volume
of water treated on that day. Continue to press  to show the maxi-
mum volume of water treated for the last 63 days. If a regeneration
occurred on the day the word "REGEN" will also be displayed. This
display will show dashes if a water meter is not installed.
Step 11D –
Twin Tank Valve transfer history: only displays when
1.0 was selected in Step 2CS. Use  or  to scroll through the last
10 tank transfers. The first position in the display ranges from 0 to 9
with the lowest number being the most recent transfer. The second
position in the display will be either "A" or "b". If "A" then the tank with
the valve on it was in service, if "b" the tank with the in/out head on
it was in service. The next three digits represent the number of hours
Step 12D –
MAV Drive History in the direction of retracted piston rod
position. Display will only be shown if 1.0 is selected in Step 2CS,
or OFF is not selected in Step 5CS. Up to a four digit number will
appear after the "L" which stands for latest and "A" which stands for
average. Drive time is measured in 1/100 of a second; i.e., a 17.10
second move is displayed as "1710". Press NEXT at any time to go
to Step 13D. Press REGEN to return to previous step.
Step 13D –
MAV Drive History in the direction of extended piston
rod position. Display will only be shown if 1.0 is selected in Step
2CS, or OFF is not selected in Step 4CS. Up to a four digit number
will appear after the "L" which stands for latest and "A" which stands
for average. Drive time is measured in 1/100 of a second; i.e., a
17.15 second move is displayed as "1715". Press and hold  and 
for 3 seconds while in Step 13D to reset the MAV drive history in both
22
PWSRTA Twin Alternating Series Softeners