Infrared Link Modul (ILM)
Safety
VDE specifications
UL/CSA approval
Climatic environmental conditions
Ambient temperature
Storage temperature
Relative humidity
Mechanical environmental conditions
Oscillation during operation
Oscillation during transportation
Degree of protection
Weight
Dimensions
Casing material
Table 4:
Environmental Conditions for the Use of the PROFIBUS ILM
Copyright
by Siemens
VDE 0806=EN60950 and IEC950
Requirements are met
0 C to )60 C
(IEC 68–2–1, IEC 68–2–2)
–40 C to )70 C
(IEC 68–2–14)
< 95% (none condensing)
(IEC 68–2–30)
If condensation forms on the window, there is a tempo-
rary reduction in the distance that can be covered.
There is no permanent functional disturbance and no
damage to the electronics if the threaded cable inlet ful-
fills the requirements of IP65.
10 to 58 Hz, 0.075 mm deflection
2
58 to 150 Hz, 10 m/s
(IEC 68–2–6)
5 to 9 Hz, 3.5 mm deflection
2
(1g) acceleration
9 to 500 Hz, 10m/s
IP 65
800 g
175
80
58 mm
Die-cast aluminum
48
6ZB530–3AC30–0BA1
(1g) acceleration