Position of the hook and needle
Fig. 36: Setting the needle bar height
(1) - Needle bar
(2) - Screw
To set the needle bar height:
1. Execute the service routine Needle-Hook > Needlebar ( p. 14).
 The software is used to define the necessary presettings on
2. Lock the machine in place at position 1 ( p. 25).
3. Remove the head cover ( p. 19).
4. Loosen the screw (2) of the needle bar (1).
5. Move the height of the needle bar (1) such that the hook tip (4) is in
6. Tighten the screw (2) for the needle bar (1).
7. Finish the service routine.
Service Instructions 869-M PREMIUM - 00.0 - 07/2018
the machine.
the middle of the lower third of the groove for the needle.
When doing so, take care not to twist the needle to the side.
The groove (3) must face toward the hook.
(3) - Needle groove
(4) - Hook tip