160
Code Type
Meaning
2131 Error
DA stepper card X Init error
2152 Error
DA stepper card X excess
current
2201 Error
DA stepper card Y reference run
timeout
2205 Error
DA stepper card Y step losses
2221 Error
DA stepper card Y encoder plug
(Sub-D, 9-pin) not connected
2222 Error
DA stepper card Y flywheel
position not found
2230 Error
DA stepper card Y not
responding
2231 Error
DA stepper card Y Init error
2252 Error
DA stepper card Y excess
current
2271 Error
DA stepper card Y watchdog
(sewing foot lift)
2301 Error
DA stepper card Z reference run
timeout (foot stroke)
2305 Error
DA stepper card Z step losses
2321 Error
DA stepper card Z encoder plug
(Sub-D, 9-pin) not connected
2322 Error
DA stepper card Z flywheel
position not found
2330 Error
DA stepper card Z not
responding
2331 Error
DA stepper card Z Init error
2352 Error
DA stepper card Z excess current • Eliminate stiff movement in
Remedial action
• Performing a software
update
• Check selection of machine
class
• Eliminate stiff movement in
the sewing machine
• Check reference sensor
• Eliminate stiff movement in
the sewing machine
• Connect encoder cable to
the control, use the correct
interface
• Check connection cables
• Check stepper motor 2 for
stiff movement
• Performing a software
update
• Replace control
• Performing a software
update
• Check selection of machine
class
• Eliminate stiff movement in
the sewing machine
• Performing a software
update
• Check selection of machine
class
• Check reference sensor
• Eliminate stiff movement in
the sewing machine
• Connect encoder cable to
the control, use the correct
interface
• Check stepper motor 1 for
stiff movement
• Performing a software
update
• Replace control
• Performing a software
update
• Check selection of machine
class
the sewing machine