DURKOPP ADLER 869-M Premium Service Instructions Manual page 102

Table of Contents

Advertisement

Menu item
Option
PWM Config
NSB
100
Setting options
Mode of thread clamp
0 – at seam start only
1 – at seam start and during reversal
2 – at seam start and during sewing foot lift
3 – at seam start and during reversal and sewing foot lift
Pulse width modulation
Power supply to the magnet for the thread clamp
t1 [ms]
Activation duration of thread clamp in time period t1.
(Value range 000 – 1000 [ms])
DtyC. t1 [%]
Duty cycle in time period t1
(Value range 000 – 1000 [%])
t2 [s]
Activation duration of thread clamp in time period t2.
(Value range 000 – 1000 [ms])
DtyC. t2 [%]
Duty cycle in time period t2
(Value range 000 – 1000 [%])
Neat Seam Beginning
(Value range: On/Off)
Trim Delay
Delay after thread cutting, when NSB is activated.
(Value range 0000 – 1000 [ms])
Knife
Value for the first position of the knife after seam start.
(Value range 000 – 359)
Knife Clamp
Value for switching off the knife clamp.
(Value range 000 – 359)
Exhaust
Exhaust removal of the cut-off remaining thread.
On° – Position for the start of exhaust removal
(value range 000 – 359)
Off – Duration of the exhaust removal
(value range 00000 – 99999 [ms])