3. For replacing an existing display: remove the exiting display by pulling it straight upwards.
The display plugs easily off the main EE220 electronics board.
4. Place the display connecting leads onto the sockets on the main electronic board while
observing its orientation (Fig. 7). Push the display gently straight down to plug it in. Observe
the ESD regulations while doing this.
5. Remove the protection foil from display (Fig. 8).
6. Power on the EE220 and check the display functionality.
7. Place back the EE220 front cover and fix it with the four screws.

13 Spare Parts and Accessories

See also data sheet "Accessories"
Description
• Display and metal front cover
• Display and polycarbonate front cover
• Duct mounting kit
• Reference probes set (2 probes)
• Extension cable for EE07 2m (6.6 ft) / 5 m (16.4 ft) / 10 m (32.8 ft) HA010801/02/03
• Connection cable for EE03 2 m
• Bracket for rail installation (polycarbonate enclosure only)
• Power supply adapter
• Radiation shield
• Drip water protection
• Plastic protection cap for EE07 probes
• Protection cap for M12 connecting cable female
• Protection cap for M12 probe connector male
• Wall mounting clip Ø 12 mm
• EE-PCA
• EE-PCS
14
"Display"
Fig. 7
Display orientation
Fig. 8
Remove protection foil from display.
/ 5 m
(6.6 ft)
(16.4 ft)
for EE07
(0.47")
Operating instructions for EE220 humidity / temperature transmitter
order Code
D07M
D07P
HA010209
HA010403
HA010328/29
HA010203
V03
HA010502
HA010503
HA010783
HA010781
HA010782
HA010211
see data sheet „EE-PCA"
EE-PCS (download at
www.epluse.com/configurator)