Supply Air Temp. Sensor (Ntc 15) - Maico WS 170 L Manual

Heat recovery systems
Table of Contents

Advertisement

Available languages

Available languages

UK │ 6. Installation ‒ Connection options
6.14 Connection option 7: WS 170
with RLS 1 WR or RLS D1 WR and

supply air temp. sensor (NTC 15)

Refer also to the wiring diagram in the
appendix
A
WS 170 electronic slide-in module
A2
Control circuit board: Jumper 8
bridged (= factory setting)
B
RLS D1 WR room air control
B1
RLS 1 WR room air control
GW1
Gateway frost protection heating
register
GW2
Gateway bypass shutter
(only WS 170 bypass unit)
T1
Supply air temperature sensor in
supply air channel (provided by
customer)
W1
230 V AC connection cable
W2, W2´ Control cable for room air control
W6
Connection cable of supply air
temperature sensor. Connection on
GW1 circuit board to KL2 terminals.
62
For WS 170 in passive-energy hou-
ses, an NTC 15 must also be instal-
led to protect against icing over (if
the supply air is too cold). The venti-
lation unit then switches off at supply
air temperatures of less than 6 °C.
Only in Comfort and Bypass units
when deploying a supply air tem-
perature sensor:
Remove the resistor on GW1 circuit
board at the KL2 terminals.

Advertisement

Table of Contents
loading

Table of Contents