Maico WS 170 L Operating And Maintenance Instructions Manual

Heat recovery systems
Hide thumbs Also See for WS 170 L:
Table of Contents

Advertisement

Available languages

Available languages

Quick Links

Wärmerückgewinnungssysteme
Heat recovery systems
Systèmes de récupération de chaleur
WS 170 L
WS 170 R
WS 170 KL
WS 170 KR
WS 170 KBL
WS 170 KBR
w w w . m a i c o - v e n t i l a t o r e n . c o m
Betriebs- und
Wartungsanleitung
Operating and
Maintenance
instructions
Notice d'utilisation
et d'entretien
D
GB
F

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the WS 170 L and is the answer not in the manual?

Questions and answers

Summary of Contents for Maico WS 170 L

  • Page 1 Wärmerückgewinnungssysteme Heat recovery systems Systèmes de récupération de chaleur WS 170 L WS 170 R WS 170 KL WS 170 KR WS 170 KBL WS 170 KBR Betriebs- und Wartungsanleitung Operating and Maintenance instructions Notice d'utilisation et d'entretien  w w w . m a i c o - v e n t i l a t o r e n . c o m...
  • Page 2 WS 170 avec Left-hand version Produkt. équipement maximal : (mirrored version) Im Internet R Version droite unter maico- Outside air Version gauche ventilatoren. II Supply air into living areas (exécution inversée) com. III Exhaust air from living Air extérieur areas II Air entrant dans les pièces...
  • Page 4: Table Of Contents

    5.2 Hygrostat HY 5 ........ 11 R = Rechtsausführung, L = Linksausführung 6. Reinigung, Wartung ....... 11 WS 170 R, WS 170 L: Standardgerät mit 6.1 Sicherheitshinweise ......11 Raumluftsteuerung RLS 1 WR und 2x G4-Filter. 6.2 Luftfilterwechsel ......11 WS 170 KR, WS 170 KL: Komfortgerät mit...
  • Page 5: Systemübersicht

    2. Produktinformationen │ de Pos. Bezeichnung Funktion 2.2 Systemübersicht Elektronik- Enthält die Steuer- Abbildung A: WS 170 in Rechtsausführung einschub platine und optionale Abbildungsbeispiel WS 170 KBR Zusatzplatinen für Ohne Abbildung: WS 170 in Linksausführung Heizregister oder mit spiegelbildlicher Bauweise Bypassklappe.
  • Page 6: Steuerungen, Sensoren

    Bypassparameter. -Sensor Erfasst den Kohlen- 2.5 Vorhersehbare Fehlanwendungen dioxidgehalt „CO “. (optional) Maico haftet nicht für Schäden durch bestim- Frischluftzufuhr erfolgt mungswidrigen Gebrauch. Gerät auf keinen abhängig vom CO Fall einsetzen: Gehalt im Raum. ● während der Bauphase. Luftqualitäts- Steuert das Gerät...
  • Page 7: Sicherheitshinweise

    3. Sicherheitshinweise │ de ● mit sämtlichen angebauten 3. Sicherheitshinweise Rohranschlüssen (Schall- dämpfer reduzieren die 3.1 Allgemein Lärmemissionen erheblich). ● Lassen Sie sich nach der ● bei korrekter Funktion der Installation durch Ihren Sicherheitsabschaltung. Installateur an Lüftungsgerät ● Sicherheitsabschaltung mit und Raumluftsteuerung ●...
  • Page 8: Luftfilter

    de │ 3. Sicherheitshinweise 3.2 Luftfilter 3.3 Reinigung, Wartung ● Betreiben Sie das Lüftungs- ● Trennen Sie das Lüftungs- gerät niemals ohne Luftfilter. gerät vor Reinigungs- und ● Überprüfen Sie die Luftfilter Wartungsarbeiten vom Netz (schalten Sie die Sicherung regelmäßig auf Verschmut- im Sicherungskasten aus).
  • Page 9: Bestimmungen Für Den Betrieb Mit Feuerstätten

    3. Sicherheitshinweise │ de Bei raumluftabhängigen 3.5 Bestimmungen für den Feuerstätten für feste Brenn- Betrieb mit Feuerstätten stoffe muss im Auslösefall der Sicherheitseinrichtung die 3.5.1 Lüftungstechnische An- Lüftungsanlage abgeschaltet forderungen an Feuerstätten werden. WS 170-Lüftungsgeräte dürfen in Räumen, Wohnungen WS 170-Lüftungsgeräte oder Nutzungseinheiten ver- dürfen nicht installiert gleichbarer Größe, in denen...
  • Page 10: Bedienung

    de │ 3. Sicherheitshinweise 3.5.2 Brandschutz- 4. Bedienung anforderungen Hinsichtlich der brandschutz- 4.1 Raumluftsteuerungen ● WS 170-Standardgerät: RLS 1 WR technischen Installationsvor- ● WS 170-Komfortgerät: RLS 1 WR schriften für die Errichtung der ● WS 170-Bypassgerät: RLS D1 WR Lüftungsanlage sind die landes- (digital) rechtlichen Regelungen, insbe- sondere die bauaufsichtliche...
  • Page 11 4. Bedienung │ de Das Lüftungsgerät schaltet jeweils eine Stufe Stufe Funktion ▲ / ▼ zurück: ● Lüftungsstufe 3 ● Lüftungsstufe 2 Nennlüftung in Lüftungsstufe 2 ● Lüftungsstufe 1/Dauerbetrieb LED 2 leuchtet, das Lüftungsgerät ● Lüftungsstufe 1/Intervallbetrieb läuft in Lüftungsstufe 2. Intensivlüftung in Lüftungsstufe 3 4.2.3 Lüftungsgerät ausschalten LED 3 leuchtet, das Lüftungsgerät...
  • Page 12: Raumluftsteuerung Rls D1 Wr

    de │ 4. Bedienung 4.2.5 Bedeutung der LEDs 4.3 Digitale Raumluftsteuerung RLS D1 WR Für Störungen und deren Beseitigung  Kapitel 7. Bedeutung Alle LEDs aus. Lüftungsgerät im Standby-Modus. LED 1, 2 oder 3 Anzeige reduzierte leuchtet ständig. Lüftung, Nennlüftung Für detaillierte Informationen zu Funktionen und Einstellungen ...
  • Page 13: Optionale Systemkomponenten

    5. Optionale Systemkomponenten │ de Zulässig ist der Anschluss von 5. Optionale Systemkomponenten 1x CO -Sensor oder 1x VOC-Sensor oder mehrerer HY 5. 5.1 CO -Sensor (SKD) / VOC-Sensor (Luftqualitätsregler EAQ 10/2) Sensor zur Erfassung von Kohlendioxid. 6. Reinigung, Wartung Der CO -Gehalt der Luft gilt als Indikator für die Raumluftqualität.
  • Page 14 de │ 6. Reinigung, Wartung An der Raumluftsteuerung wird alle 8. Entsorgen Sie den Pollenfilter gemäß den 3 Monate Filterwechsel angezeigt. örtlichen Bestimmungen. Wir empfehlen spätestens alle 6 Monate die Filter zu wechseln. Beschädigung des Pollen- ACHTUNG Der Filterwechsel ist einfach und filters, falls dieser in der Mitte ohne Werkzeug durchführbar.
  • Page 15: Lüftungsgerät Reinigen

    6. Reinigung, Wartung │ de 6. Schieben Sie den gereinigten Wärme- 6.3 Lüftungsgerät reinigen tauscher vorsichtig bis zum Anschlag in Wartungsintervalle das Gehäuse  Positionsaufkleber auf Abhängig vom Verschmutzungsgrad der Frontseite. empfehlen wir eine: 7. Hängen Sie die Frontabdeckung ein und ●...
  • Page 16: Störungen, Meldungen

    de │ 7. Störungen, Meldungen 7.2.2 Ventilatorausfall 7. Störungen, Meldungen Bei Ausfall einer der beiden Ventilatoren (keine Drehzahl) erscheint nach ca. 1 Minute 7.1 Filterwechselanzeige an der Raumluftsteuerung RLS 1 WR eine An der Raumluftsteuerung wird alle 3 Monate Störungsmeldung (alle 3 LEDs blinken). Filterwechsel angezeigt.
  • Page 17: Störungen Und Deren Beseitigung Raumluftsteuerung Rls 1 Wr

    7. Störungen, Meldungen │ de 7.3 Störungen und deren Beseitigung Raumluftsteuerung RLS 1 WR Unbedingt einen Fachinstallateur hinzuziehen, wenn die Fehler- meldung nach einer Störungs- quittierung immer noch erscheint. Zur Störungsbeseitigung die Störungsmeldung an der RLS 1 WR löschen  Kapitel 7.2.1 Störung an der Mögliche Ursache Prüfung...
  • Page 18: Frostschutztemperaturen

    de │ 7. Störungen, Meldungen Störung an der Mögliche Ursache Prüfung Beseitigung RLS 1 WR Ventilatoren Differenzdruckwächter Differenzdruckwächter Feuerstätte außer Betrieb außer Betrieb. hat ausgelöst. prüfen. Auslöseursache nehmen. ermitteln. Hat der Differenzdruckwächter Keine Störungs- Differenzdruckwächter austauschen. meldung: ausgelöst, sind die Alle LEDs an der RLS 1 WR aus.
  • Page 19: Zubehör

    WS 170 KR und WS 170 KBR KWH 12 R 0152.0058 KWH 16 R 0152.0060 Kombi-Wandstutzen, Linksaus- führung, passend für WS 170 L, WS 170 KL und WS 170 KBL: KWH 12 L 0152.0059 KWH 16 L 0152.0061 Steckverbinder mit Lippen- 0055.0183...
  • Page 20: Ersatzteile

    de │ 9. Ersatzteile 9. Ersatzteile...
  • Page 21 9. Ersatzteile │ de Wichtig bei Bestellungen Bei Rückfragen Geben Sie bei Ersatzteil- Maico Elektroapparate-Fabrik GmbH Bestellungen die Artikel-Nummer Steinbeisstraße 20 und zusätzlich den Gerätetyp 78056 Villingen-Schwenningen, Deutschland und die Seriennummer des Tel. +49 7720 694 445, Fax +49 7720 694 175 Lüftungsgerätes an.
  • Page 22: Technische Daten

    de │ 10. Technische Daten 10. Technische Daten Gehäuseabmessung Bemessungsspannung 230 V AC (B x H x T) in mm Netzfrequenz 50 Hz / 60 Hz 595 x 820 x 375 ● WS 170 Standardgerät Lüftungsstufen 595 x 820 x 375 ●...
  • Page 23: General Advice

    6. Cleaning, maintenance ......29 R = right-hand version, L = left-hand version 6.1 Safety instructions ......29 WS 170 R, WS 170 L: Standard unit with 6.2 Replacing the air filter ..... 30 RLS 1 WR room air control and 2x G4 filter.
  • Page 24: System Overview

    uk │ 2. Product information Item Designation Function 2.2 System overview Electronic slide- Contains the control Figure A: WS 170 in right-hand version in module circuit board and Figure shows WS 170 KBR by way of optional extra circuit example boards for heating re- Not illustrated: WS 170 in left-hand version gister or bypass shutter.
  • Page 25: Controls, Sensors

    2. Product information │ uk 2.3 Controls, sensors 2.5 Foreseeable cases of misuse Maico is not liable for damages caused by RLS 1 WR With step switch and use contrary to the intended purpose. Under room air control filter monitoring.
  • Page 26: Air Filter

    uk │ 3. Safety instructions ● Switch the ventilation unit off are supervised by a person responsible for their safety, immediately if you discover or they have been instructed damage or faults that could about the safe operation of endanger persons or the unit and can understand property.
  • Page 27: Regulations For Operation With Fireplaces

    3. Safety instructions │ uk A filter replacement prompt 3.4 Installation, connection is displayed on the room ● Installation is only permitted air control every 3 months. when carried out by trained We recommend replacing specialists in accordance with the filter every 6 months WS 170 installation at the latest.
  • Page 28 uk │ 3. Safety instructions 2. the extraction of exhaust gas In the case of solid fuel from the air-ventilated fireplaces, any shut-off device fireplaces is monitored by may only be operated manually. special safety equipment. In It must be possible to identify the case of air-ventilated the position of the shut-off fireplaces for liquid or...
  • Page 29: Operation

    4. Operation │ uk Function ▲ / ▼ Level 4. Operation Intensive ventilation in ventilation level 3 4.1 Room air controls LED 3 lights up, the ventilation unit runs in ventilation level 3 for around ● WS 170 standard unit: RLS 1 WR 1 hour.
  • Page 30: Rls D1 Wr Room Air Control

    uk │ 4. Operation Each time the button is pressed, the 4.2.5 The meaning of the LEDs ventilation unit switches down a level: For faults and their rectification ● Ventilation level 3  Chapter 7. ● Ventilation level 2 ● Ventilation level 1/Continuous operation Meaning ●...
  • Page 31: Parallel Operation With Rls 1 Wr And Rls D1 Wr

    4. Operation │ uk and VOC sensor: The ventilation unit 4.3.2 Timer RESET for filter replacement switches between the ventilation levels, interval depending on the air quality. Filter replacement prompt is ● If the air quality improves, the ventilation displayed on the room air control unit switches over to ventilation level 1.
  • Page 32: Replacing The Air Filter

    uk │ 6. Cleaning, maintenance 4. Remove the filter inserts from the push-in 6.2 Replacing the air filter frames. Dispose of these according to Check the level of dirt on the air filter local regulations. when the filter replacement display 5.
  • Page 33: Cleaning The Ventilation Unit

    6. Cleaning, maintenance │ uk 5. Wipe the inside walls of the ventilation unit 6.3 Cleaning the ventilation unit out with a cleaning cloth. Maintenance intervals 6. Push the cleaned heat exchanger care- Depending on the level of fully into the housing as far as it will go contamination, we recommend: ...
  • Page 34: Faults, Messages

    uk │ 7. Faults, messages Briefly disconnect the ventilation unit from the 7. Faults, messages power supply for further deletion cycles. Call on the services of a specialist installer should the fault reappear. 7.1 Filter replacement display Filter replacement prompt is displayed on 7.2.2 Fan failure the room air control every 3 months.
  • Page 35: Faults And Their Rectification Rls 1 Wr Room Air Control

    7. Faults, messages │ uk 7.3 Faults and their rectification RLS 1 WR room air control Always call on the services of a specialist installer if the error message continues to appear after a fault has been acknowledged. For the fault rectification, cancel fault message on the RLS 1 WR ...
  • Page 36 uk │ 7. Faults, messages Fault on Possible cause Check Rectification RLS 1 WR Fans not Temperature sensor Check connection. Correctly connect operating. failed (not connected, Check temperature temperature sensor. Fault message: cable break or short- sensor (at 20°, the Replace temperature All 3 LEDs on the circuit).
  • Page 37: Frost Protection Temperatures

    WS 170 KR and WS 170 KBR KWH 12 R 0152.0058 KWH 16 R 0152.0060 Combi wall support, left-hand version, suitable for WS 170 L, WS 170 KL and WS 170 KBL: KWH 12 L 0152.0059 KWH 16 L 0152.0061 0055.0183...
  • Page 38: Spare Parts

    uk │ 9. Spare parts 9. Spare parts...
  • Page 39 9. Spare parts │ uk Important for orders In case of questions When ordering spare parts, Maico Elektroapparate-Fabrik GmbH state the article number as well as Steinbeisstrasse 20 the unit type and serial number of 78056 Villingen-Schwenningen, Germany the ventilation unit.
  • Page 40: Technical Data

    uk │ 10. Technical data 10. Technical data Housing dimensions Rated voltage 230 V AC (W x H x D) in mm Mains frequency 50 Hz / 60 Hz 595 x 820 x 375 ● WS 170 standard unit Ventilation levels (factory 595 x 820 x 375 ●...
  • Page 41: Remarques Générales

    R = version droite / L = version gauche 6. Nettoyage, entretien ....... 49 WS 170 R, WS 170 L : appareil standard à commande air ambiant RLS 1 WR et 2 filtre G4. 6.1 Consignes de sécurité ..... 49 6.2 Remplacement des filtres à...
  • Page 42: Aperçu Du Système

    fr │ 2. Informations produit 2.2 Aperçu du système Pos. Désignation Fonction Illustration A : WS 170 en version droite Filtre à air G4 Filtre les impuretés Exemple utilisé pour l'illustration WS 170 dans grossières de l'air. ● appareil standard Sans illustration : WS 170 en version En option dans gauche à...
  • Page 43: Commandes, Détecteurs

    2.5 Erreurs d'application prévisibles RLS 1 WR pour Modes de fonction- ● appareil nement : protection Maico décline toute responsabilité en cas de standard contre l'humidité, dommages résultant d'une utilisation non ● appareil confort niveau de ventilation conforme.
  • Page 44: Consignes De Sécurité

    fr │ 2. Informations produit ● en association avec des hottes ● Utilisez uniquement l'appareil d'extraction directement raccordées à la de ventilation : gaine d'air sortant de la ventilation ● à la tension et à la contrôlée des habitations. Du point de vue énergétique, nous fréquence indiquées sur la recommandons les hottes d'extrac- plaque signalétique.
  • Page 45: Filtres À Air

    6 mois. rigoureusement interdites et Le remplacement des dégagent Maico de toute filtres est facile et possible responsabilité ou garantie. sans outil. ● Utilisez exclusivement des filtres d'origine.
  • Page 46: Installation, Branchement

    fr │ 3. Consignes de sécurité ● Apposez un panneau d'aver- 3.5 Directives relatives à une tissement pour prévenir toute utilization avec un foyer remise en marche intempe- stive sur le coffret de fusibles. 3.5.1 Exigences devant être remplies par les foyers en matière de technique 3.4 Installation, branchement d'aération...
  • Page 47 3. Consignes de sécurité │ fr En cas de foyers dépendants 3.5.2 Mesures de protection de l'air ambiant pour des com- contre les incendies bustibles solides, l'installation En matière de protection contre de ventilation doit être arrêtée les incendies des installations dès le déclenchement du de ventilation, les règlements dispositif de sécurité.
  • Page 48: Utilisation

    fr │ 4. Utilisation Niveau Fonction ▲ / ▼ 4. Utilisation Ventilation nominale au niveau de ventilation 2 4.1 Commandes air ambiant LED 2 s'allume, l'appareil de ● Appareil standard WS 170 : RLS 1 WR ventilation fonctionne au niveau ●...
  • Page 49 4. Utilisation │ fr 4.2.2 Réglage du niveau de ventilation 4.2.4 RESET de la minuterie d'intervalle de remplacement des filtres 1. Niveau de ventilation supérieur : appuyez sur la touche ▲ jusqu'à ce que La commande air ambiant affiche la LED du niveau de ventilation souhaité tous les 3 mois un message s'allume.
  • Page 50: Mode De Fonctionnement Parallèle Avec Rls 1 Wr Et Rls D1 Wr

    fr │ 4. Utilisation 4.4 Mode de fonctionnement parallèle Signification avec RLS 1 WR et RLS D1 WR Les 3 LED clignotent Défaut. Une modification des niveaux de ventilation régulièrement à Pour y remédier  Chapitre 7. sur la commande air ambiant RLS 1 WR n'est intervalle de longue durée pas affichée sur la commande numérique...
  • Page 51: Hygrostat Hy 5

    5. Composants système optionnels │ fr Détecteur de CO et VOC : Selon la qualité 6.2 Remplacement des filtres à air de l'air, l'appareil de ventilation commute Contrôlez le degré d'encrassement entre les différents niveaux de ventilation. des filtres à air lorsque l'affichage de ●...
  • Page 52: Nettoyage De L'appareil De Ventilation

    fr │ 6. Nettoyage, entretien 3. Retirez les cadres d'encastrement des 12. Remettez à zéro (RESET) la minuterie deux filtres à air G4 de l'appareil de d'intervalle de remplacement du filtre situé sur la commande air ambiant  ventilation. Chapitre 4.2.4, Chapitre 4.3.2 ou Notice 4.
  • Page 53: Nettoyage De L'écoulement De Condensat Et Du Siphon

    6. Nettoyage, entretien │ fr 3. Retirez avec précaution l'échangeur de 6. Mettez l'appareil de ventilation en marche chaleur de l'appareil de ventilation avec à l'aide de l'interrupteur principal [6]. le ruban plastique. Après les périodes sèches 4. Ne pas nettoyer l'échangeur de chaleur prolongées, remplissez également avec des produits liquides (y compris le siphon avec de l'eau.
  • Page 54: Défauts Et Leurs Remèdes Commande Air Ambiant Rls 1 Wr

    fr │ 7. Défauts, messages ● la tension de service du ventilateur d'air Le défaut est également affiché lorsque le registre de chauffage de protection contre le sortant est désactiveé en cas de panne du gel est défectueux et lorsque la température ventilateur d'air sortant.
  • Page 55 7. Défauts, messages │ fr Défaut sur la Cause possible Vérification Remède RLS 1 WR Appuyez sur la touche ▲ Ventilateurs Pas de tension Mesurer la tension hors service. d'alimentation aux d'alimentation du pendant environ 5 secon- Toutes les 3 LED ventilateurs.
  • Page 56: Temp. De Protection Contre Le Gel

    fr │ 7. Défauts, messages Défaut sur la Cause possible Vérification Remède RLS 1 WR Ventilateurs hors Le contrôleur de Vérifier le contrôleur de Mettre le foyer hors service. différence de pression différence de pression. service. s'est déclenché. Rechercher la cause du Remplacer le contrôleur Pas de message déclenchement.
  • Page 57: Accessoires

    WS 170 KR et WS 170 KBR KWH 12 R 0152.0058 KWH 16 R 0152.0060 Raccord mural combiné (version gauche) adaptée à WS 170 L, WS 170 KL et WS 170 KBL: KWH 12 L 0152.0059 KWH 16 L 0152.0061 Raccord enfichable avec joint 0055.0183...
  • Page 58: Pièces De Rechange

    fr │ 9. Pièces de rechange 9. Pièces de rechange...
  • Page 59 9. Pièces de rechange │ fr Important pour la commande Adressez vos questions à : Pour commander des pièces de Maico Elektroapparate-Fabrik GmbH rechange, indiquez le numéro de Steinbeisstraße 20 référence ainsi que le type et le 78056 Villingen-Schwenningen, Allemagne numéro de série de l'appareil de...
  • Page 60: Caractéristiques Techniques

    fr │ 9. Pièces de rechange Humidité admise sur le lieu Cache de protec- d'installation (à 20 °C) tion avant pour ● appareil standard 50 % HR appareil bypass ● appareil confort 70 % HR (avec canal ● appareil bypass 70 % HR bypass) : Version droite...
  • Page 61: Élimination

    fr │ 11. Élimination 11. Élimination Emballage Ne pas éliminer avec les ordures ménagères. L'appareil contient des substances recyclables ainsi que des substances qui ne doivent pas être mêlées aux ordures ménagères. Mettez les matériaux d'emballage au rebut conformément aux dispositions en vigueur dans votre pays.
  • Page 62 Maico Elektroapparate-Fabrik GmbH • Steinbeisstr. 20 • 78056 Villingen-Schwenningen • Germany • Service +49 7720 694 447 • technik@maico.de...