Maico WS 170 KR Wiring Diagram

Advertisement

Quick Links

WIRING DIAGRAM

WS 170 KR
WS 170 KR and WS 170 KL wiring diagram
A
A 1
A 3
K L 6
K L 4
K L 3
J 2
W 6
W 5
A B L
Z U L
W 3
T - m i n
W 4
Version: 2019-08-30 - MAICO VENTILATOREN, www.maico-fans.com - We are not responsible for mistakes or printing errors and retain the
right to make technical modifications without giving prior notice
L
N
P E
W 1
W 2
W 2
1 a
2 a
S 1
1
2
S
S
L
L N N
L ' L '
N ' N '
P E P E
1
2
3
4
5
X 1
L
L N N
L ' L '
N ' N '
P E P E
K L 5
G W 1
K L 2
K L 1
G Y
G N Y E
P K
B U
W H
B N
B N
W H
B K
B N
W 4 / + 2 4 V
G N
J 1
Y E
B N
B U
A 2
T e m p
G N Y E
B N
B D E
O n / O f f
B U
C O 2
G N Y E
W H
R D
k 1
Y E
B U
B U
W H
W H
R D
G N D
Y E
0 - 1 0 V
B U
+ 2 4 V
S 1
S 3
S 1
S 3
S 2
S 2
Z u l u f t
A b l u f t
0 - 1 0 V
( M 1 )
0 - 1 0 V
( M 2 )
I I I
P K
L D 3
I I
W H
L D 2
B N
I
L D 1
B
B 1
G Y
Y E
S 1 +
G N
S 2 -
W 2 '
M 2
A B L
M 1
Z U L
Page 1

Advertisement

loading
Need help?

Need help?

Do you have a question about the WS 170 KR and is the answer not in the manual?

Questions and answers

Summary of Contents for Maico WS 170 KR

  • Page 1: Wiring Diagram

    ( M 1 ) 0 - 1 0 V ( M 2 ) Version: 2019-08-30 - MAICO VENTILATOREN, www.maico-fans.com - We are not responsible for mistakes or printing errors and retain the Page 1 right to make technical modifications without giving prior notice...
  • Page 2 W6 - Connection cable (provided by customer) for external supply air temperature sensor. Sensor type=NTC 10k. Re- move 12k resistor on GW1 circuit board. Version: 2019-08-30 - MAICO VENTILATOREN, www.maico-fans.com - We are not responsible for mistakes or printing errors and retain the Page 2...
  • Page 3 Room air control RLS 1 WR can also be connected to room air control RLS D1 WR. No need for distributor "V" if only one RLS 1 WR room air control is connected. Version: 2019-08-30 - MAICO VENTILATOREN, www.maico-fans.com - We are not responsible for mistakes or printing errors and retain the Page 3...
  • Page 4 W1 - 230 V AC connection cable W2 - Control cable for room air control, shielded control cable Version: 2019-08-30 - MAICO VENTILATOREN, www.maico-fans.com - We are not responsible for mistakes or printing errors and retain the Page 4 right to make technical modifications without giving prior notice...
  • Page 5 Relay contact “k1” is closed when the ventilation unit is running. Maximum load-bearing capacity for relay contact k1 = 3A / 250 V AC, 2A / 30 V DC. Version: 2019-08-30 - MAICO VENTILATOREN, www.maico-fans.com - We are not responsible for mistakes or printing errors and retain the Page 5...
  • Page 6 If a CO2/VOC sensor is connected, only one RLS 1 WR room air control may be connected. Never operate an EAQ 10/2 air quality sensor together with a CO2 sensor. Version: 2019-08-30 - MAICO VENTILATOREN, www.maico-fans.com - We are not responsible for mistakes or printing errors and retain the Page 6...
  • Page 7 Set the switching point at the hygrostat manually. Never connect a hygrostat and a CO2 sensor/VOC sensor at the same time. Version: 2019-08-30 - MAICO VENTILATOREN, www.maico-fans.com - We are not responsible for mistakes or printing errors and retain the Page 7...
  • Page 8 The ventilation unit runs again at the same ventilation level as before it was blocked. Version: 2019-08-30 - MAICO VENTILATOREN, www.maico-fans.com - We are not responsible for mistakes or printing errors and retain the Page 8...
  • Page 9 Only in Comfort and Bypass units when deploying a supply air temperature sensor: Remove the resistor on GW1 cir- cuit board at the KL2 terminals. Version: 2019-08-30 - MAICO VENTILATOREN, www.maico-fans.com - We are not responsible for mistakes or printing errors and retain the Page 9...

This manual is also suitable for:

Ws 170 kl