( M 1 ) 0 - 1 0 V ( M 2 ) Version: 2019-08-30 - MAICO VENTILATOREN, www.maico-fans.com - We are not responsible for mistakes or printing errors and retain the Page 1 right to make technical modifications without giving prior notice...
Page 2
W6 - Connection cable (provided by customer) for external supply air temperature sensor. Sensor type=NTC 10k. Re- move 12k resistor on GW1 circuit board. Version: 2019-08-30 - MAICO VENTILATOREN, www.maico-fans.com - We are not responsible for mistakes or printing errors and retain the Page 2...
Page 3
Room air control RLS 1 WR can also be connected to room air control RLS D1 WR. No need for distributor "V" if only one RLS 1 WR room air control is connected. Version: 2019-08-30 - MAICO VENTILATOREN, www.maico-fans.com - We are not responsible for mistakes or printing errors and retain the Page 3...
Page 4
W1 - 230 V AC connection cable W2 - Control cable for room air control, shielded control cable Version: 2019-08-30 - MAICO VENTILATOREN, www.maico-fans.com - We are not responsible for mistakes or printing errors and retain the Page 4 right to make technical modifications without giving prior notice...
Page 5
Relay contact “k1” is closed when the ventilation unit is running. Maximum load-bearing capacity for relay contact k1 = 3A / 250 V AC, 2A / 30 V DC. Version: 2019-08-30 - MAICO VENTILATOREN, www.maico-fans.com - We are not responsible for mistakes or printing errors and retain the Page 5...
Page 6
If a CO2/VOC sensor is connected, only one RLS 1 WR room air control may be connected. Never operate an EAQ 10/2 air quality sensor together with a CO2 sensor. Version: 2019-08-30 - MAICO VENTILATOREN, www.maico-fans.com - We are not responsible for mistakes or printing errors and retain the Page 6...
Page 7
Set the switching point at the hygrostat manually. Never connect a hygrostat and a CO2 sensor/VOC sensor at the same time. Version: 2019-08-30 - MAICO VENTILATOREN, www.maico-fans.com - We are not responsible for mistakes or printing errors and retain the Page 7...
Page 8
The ventilation unit runs again at the same ventilation level as before it was blocked. Version: 2019-08-30 - MAICO VENTILATOREN, www.maico-fans.com - We are not responsible for mistakes or printing errors and retain the Page 8...
Page 9
Only in Comfort and Bypass units when deploying a supply air temperature sensor: Remove the resistor on GW1 cir- cuit board at the KL2 terminals. Version: 2019-08-30 - MAICO VENTILATOREN, www.maico-fans.com - We are not responsible for mistakes or printing errors and retain the Page 9...