Air Volume Settings; Cleaning, Filter Change; Accessories - Maico ALD 10 T Mounting Instructions

Outside wall air opening
Hide thumbs Also See for ALD 10 T:
Table of Contents

Advertisement

Available languages

Available languages

UK │ Settings, Cleaning, Filter change

7. Air volume settings

In general, the internal cover [8] or cover [12]
of the thermovalve is usually open so that the
inside of the building is always supplied with
fresh air. The required air volume is shown in
the characteristic curves in Chapter 12.
ALD 10
1. Position the internal cover slider [8] so that
the necessary air volume is observed. The
slider position needed to ensure this air
volume is shown in Chapter 12.
2. The iris closure of the ALD opens/closes
depending on the setting.
● CLOSED = Slider all the way to the left
● AUF = Slider all the way to the right
ALD 10 T
1. Position cover [12] of the thermovalve so
that the necessary air volume is observed.
The opening gap [in mm] needed to en-
sure this air volume is shown in Chap. 12.
At temperatures of less than 10 °C
the gap changes by ± 1 mm per 1 K
(minimum space 4 mm).

8. Cleaning, filter change

For air filter article numbers
 Chapter 9.
Air filter
Task
G2 air filter
Wash out with clean water
(dust filter)
or exhaust if slightly dirty.
Replace with new one if
very dirty. Insert only dry
filter.
8.1 Quarterly
Check/Change the air filter [7] or [11]
quarterly as follows.
1. Take off the internal cover [8]/cover [12].
2. ALD 10: Take the filter holder and the
air filter out of the connection socket.
ALD 10 T: Take the air filter out of the
connection socket.
14
3. Clean or replace air filter according to the
table in Chapter 8.
4. In the case of heavy soiling, clean the
complete air channel and all of the
housing components with a vacuum
cleaner.
5. Insert air filter (for ALD 10 incl. both filter
holders) in the connection socket.
6. ALD 10: Press internal cover [8] onto
connection socket until it snaps into place.
Mind the slider slot. Observe the setting
position ( Chapter 7).
ALD 10 T: Screw on cover [12]. Observe
the setting position ( Chapter 7).
8.2 Annually
For reasons of hygiene, replace the air filter
annually with a new one, Chapter 8.1.

9. Accessories

Accessories / Product type
ALDF 10:
Replacement filter, filter class
G2, 5 items per packing unit
ALDF 10 T:
Replacement filter, filter class
G2, 5 items per packing unit
ALDS 10
Storm protection
In the case of questions:
Maico Elektroapparate-Fabrik GmbH
Steinbeisstraße 20
78056 Villingen-Schwenningen,
Germany
Tel. +49 (0)7720 694445
Fax +49 (0)7720 694175
E-Mail: ersatzteilservice@maico.de
Article no.
0093.0154
0093.0155
0152.0056