The printer requires a 3-phase, 208 VAC, 50/60 Hz, 10 kVA power source .
Ceiling drop lines for nitrogen supply and exhaust, electrical, and clean dry air (CDA) are recommended. The floor below the
process station must be flat and vibration-free. The room must be air-conditioned, with no vents directly above the machine.
Clearance around the process station is required so hinged access panels can be fully opened . See the ProX
Printer Facility Requirements Poster in section 14 of this Facility Guide for clearance requirements .
A
B
3D Systems, Inc.
D
C
E
A
Stacklight: Indicates the state of the
system .
Print Chamber Area: There are two doors
B
in front of the Print Chamber—the outer
locking door, and the inner print chamber
door . The parts are printed inside the Print
Chamber .
F
E-Stop: The Emergency Stop button is a
C
safety mechanism used to shut off the
machine in an emergency situation in which
it cannot be shut down in the usual
manner .
User Interface (UI): The user controls the
D
system using a monitor located on the front
panel .
LED Interface Lights and Controls: There
E
are three LED's which give the user visual
feedback regarding the system . The two
buttons allow the user to control the
chamber lights and enable the system .
There is (1) standard USB ports beneath
the LED's . .
User and Service Access Panels: There are
F
two types of panels on the sides and back
of the machine—user access and service
access . The user access panels are hinged
doors . The service access panels are lift-off
panels . A tool is required to open each
service panel .