Scilogex DM0636 User Manual

Scilogex DM0636 User Manual

Multi-purpose centrifuge

Advertisement

DM0636
Multi-purpose Centrifuge
Before using centrifuge, please carefully read this user manual for its efficient operation and safety.

Advertisement

Table of Contents
loading

Summary of Contents for Scilogex DM0636

  • Page 1 DM0636 Multi-purpose Centrifuge Before using centrifuge, please carefully read this user manual for its efficient operation and safety.
  • Page 2: Table Of Contents

    USER MANUAL Contents Copyright: ................................ 0 Safety Reminder .............................. 1. Specifications ............................... 3 2. Declaration of Conformity ........................... 3 3. Required Operational Condition ........................4 3.1 Basic operational Conditions ......................4 3.2 Transport and storage condition ......................4 4. Installation ..............................4 4.1 Location ..............................
  • Page 3 USER MANUAL...
  • Page 5: Copyright

    Copyright: No part of this manual may be reproduced or transmitted without prior written permission of original manufacture. We can not be responsible to inform at real-time if the outline and specifications of centrifuge is subject to change for improvement. VERSION201510...
  • Page 6: Safety Reminder

    USER MANUAL Safety Reminder Common safety precautions Carefully read the following safety precautions for a thorough understanding.  Follow the instructions and procedures described in this manual to operate this centrifuge safely.  Carefully read all safety messages in this manual and the safety instructions on the instrument. ...
  • Page 7 USER MANUAL  Make sure to prepare necessary safety measures before using samples that are toxic, radioactive or contaminated with pathogenic micro-organisms at your own responsibility.  If the instrument, rotor and/or accessories that has been contaminated by solutions with toxic, radioactive or pathogenic materials, clean it according to the decontamination procedure that you are specified.
  • Page 8: Specifications

    USER MANUAL 1. Specifications Maximum speed 6000rpm(300-6000rpm), increment: 10rpm ±20rpm Speed accuracy Maximum RCF 4020× g, increment: 10× g Maximum capacity 100ml× 4(swing out rotor), 50ml× 6(angle fix rotor) Rotor types Swing out rotor: 100ml× 4, micro plate rotor Angle rotor: 2.0ml× 30, 2.0ml× 60, 5.0mlV× 18, 50mlV× 6, pcr8× 12, 15ml×...
  • Page 9: Required Operational Condition

    USER MANUAL NOTE: This centrifuge has been tested and found to comply with the limits for a Class A digital device, pursuant to Part 15 of the FCC Rules. These limits are designed to provide reasonable protection against harmful interference when the centrifuge is operated in a commercial environment. The centrifuge generates, uses, and can radiate radio frequency energy and, if not installed and used in accordance with the user manual, may cause harmful interference to radio communications.
  • Page 10: Location

    USER MANUAL 4.1 Location (1)Place the centrifuge on a firm, flat and level table, ensure the four feet of this centrifuge stand on the table firmly. Avoid installing on the slippery surface or surface prone to vibration. (2)Ideal ambient temperature is 20℃±5℃, avoid placing the centrifuge in direct sunlight if temperature exceeds 30℃.
  • Page 11: Operation Panel

    USER MANUAL View Door hole Air vents Figure 5.2 D1536 back view of the centrifuge 6. Operation panel Speed Temperature Time Acceleration Deceleration Memory Figure 6-1 Operation Panel Item Symbol Name Function When the door closed, press and hold the key to accelerate Pulse key running, release the key to stop it.
  • Page 12: Rotor Preparation

    USER MANUAL Press the key to set the deceleration curve. Deceleration key 0: inertial braking. 9: fastest braking. Load program: Press the key shortly to load the program Memory key Save program: Press and hold key for 5 seconds Clockwise rotate to increase parameter values. counter- clockwise rotate to decrease parameter values.
  • Page 13: Inspect The Rotor

    USER MANUAL imbalance is not exceeded. 7.4 Inspect the rotor Check the rotor for corrosion or scratches before using. CAUTION:  If any abnormality such as corrosions or scratches are found, stop using the rotor and contact our service center. ...
  • Page 14 USER MANUAL After self-checking, instrument will display accumulative running time, see figure below: Figure Accumulative running time interface Figure 8-2 indicates the centrifuge has accumulated running time 1657 hours 12 minutes and 9 seconds, and then the centrifuge displays the last running values, see figure 8-3 below: Figure Last running interface ...
  • Page 15 USER MANUAL stuck between the rotor and the shaft. Double check and clean it if necessary.  Rotate the rotor slightly with your fingers to check if the rotor vibrates. If so reinstall the rotor again.  Rotate the nut clockwise using the wrench to tighten the rotor to the shaft firmly. ...
  • Page 16 USER MANUAL (4) Set program There are 1 ~ 9 program groups.  Saving the program Press and hold the key more than 5 seconds, the current parameters are saved under the selected program number.  Loading the program Press the key shortly, the program number will be increasing, from 1 to 9, then from 9 to 1, the corresponding parameters changing as well.
  • Page 17: Rcf Operation

    USER MANUAL 8.2 RCF Operation (1)Turn on the power switch. (2)Set a RCF (Relative Centrifugal Force) value. CAUTION: ● Do not exceed the allowable maximum RCF value of the rotor and adapters.  and choose speed unit ×g, the speed symbol will flash into RCF value input status. Press the key ...
  • Page 18: Consumables

    USER MANUAL  If the centrifuge needs cleaning, clean it with a cloth or sponge moistened with a neutral detergent solution.  Sterilize the centrifuge by wiping with a cloth moistened with 70% ethanol solution. (2) Rotor chamber CAUTION  Do not directly pour water, neutral detergent or disinfectant solution into the rotor chamber.
  • Page 19: Routine Inspection

    USER MANUAL rings may fall off or aging after several autoclaving, need to be replaced or re-installed. Seal ring 2 Seal ring 1 2 Figure 9-1 Seal rings of rotor 9.3.2 Replacement methods (1)Clean the seal ring slot with neutral detergent solution and make it dry. (2)...
  • Page 20: How To Open The Door

    USER MANUAL E-02 · The door opened in running. · Close the door immediately. · Close the door , and then start to Door fault · Press the key while the operate. door opening. · The centrifuge can not identify the ·Reconfirm the ID code of the rotor and E-03 ROTOR ID...
  • Page 21: Replacement Of Fuses

    USER MANUAL  Two holes are located on the both sides in the top right corner of the cover.  Insert a screw driver into the hole and push forward to release the door. 10.3 Replacement of fuses  (1)There are two fuses, 250V, 6.3A time-delay type size: Ф5×20.
  • Page 22 USER MANUAL Max. Max. RCF Max.centrifugal radius Rotor type Tube/bottle Adapter speed code Rcf (× g) (cm) (rpm) 2/1.5ml ×30 6000 4020 0.2ml ×30 AS30-2 A02P2 6000 3415 0.5ml×30 A05P2 6000 3618 2/1.5ml ×60 6000 4020 0.2ml×60 A02P2 6000 3415 AS60-2 0.5ml×60 3618...
  • Page 23: Tubes

    USER MANUAL (3)If some samples leaked in the rotor hole, wash the hole with water, apply a thin coat of silicon grease on the rotor surface after drying. (4)It is necessary for a regular maintenance for rotor, recommend to clean it each 3 months to keep cleaning of tube hole and shaft hole, and then apply a thin coat of silicon grease on it.
  • Page 24: Calculate Relative Centrifuge Force(Rcf)

    USER MANUAL PA: Polyallomer;PC:Polycarbonate;PP:Polypropylene 11.2.2 Cleaning PC tubes PC materials are low in chemical resistance against alkaline solutions. Avoid using neutral detergents with pH higher than 9. Note that pH of some neutral detergents are still higher than 9 even if diluted according to the instruction in the maker‟s catalog.
  • Page 25: Ordering Information

    USER MANUAL 13. Ordering information Cat. No. Model Descriptions Multi-purpose Centrifuge,with SE4-100 rotor kits, US plug, 912015137777 DM0636 110V/50Hz/60Hz Multi-purpose Centrifuge,with SE4-100 rotor kits, Cn plug, 91211517777 DM0636 220V/50Hz/60Hz Multi-purpose Centrifuge,with SE4-100 rotor kits, Euro plug , 912215127777 DM0636 220V/50Hz/60Hz Multi-purpose Centrifuge,with SE4-100 rotor kits, UK plug,...
  • Page 26: Warranty

    USER MANUAL 30pcs/pk 9 hole-bucket assembly 4 hole-bucket assembly 2 hole-bucket assembly 1 hole-bucket assembly 14. Warranty 14.1 Warranty of the centrifuge This centrifuge is guaranteed for two years from the date of delivery provided that it has been operated and maintained properly.
  • Page 27 USER MANUAL SCILOGEX, LLC 1275 Cromwell Ave., Suite C6, Rocky Hill, CT, 06067 United States. Office: +1-860-436-9221 Fax: +1-860-436-9745 Sales/service contact: info@scilogex.com www.scilogex.com...

Table of Contents