Download Print this page
Optex OA-AXIS I Operation Manual

Optex OA-AXIS I Operation Manual

Motion detector for automatic doors

Advertisement

Quick Links

OA-AXIS I / II
MANUFACTURER'S STATEMENT
Read this operation manual carefully before use to ensure proper operation of the sensor.
Failure to read this operation manual may cause improper sensor operation and may result in serious injury or death of
person.The meanings of the symbols are as follows. Please study the following first and then read the contents of this
operation manual.
Disregard of warning may cause the improper operation causing death or serious injury of
WARNING
person.
Disregard of caution may cause the improper operation causing injury of person or damage to
CAUTION
objects.
NOTE
Special attention is required to the section of this symbol.
NO TE
1. This sensor is a non-contact switch intended for header mount / wall mount of an automatic door.
Do not use for any other applications. This sensor cannot be used for industrial doors or shutters,
when used, proper operation and safety cannot be guaranteed.
2. When setting the sensor's detection area, make sure there is no traffic around the installation site.
3. Before turning the power on, check the wiring to prevent damage or malfunction of equipments that are connected
to the sensor.
4. Only use the sensor as specified in the operation manual provided.
5. Be sure to install the sensor in accordance with the local laws and standards of the country in which the sensor is
installed.
6. Before leaving the job site make sure that the sensor is operating properly and instruct the building owner/operator
on proper operation of the door and the sensor.
7.The sensor setting can only be changed by an installer or service engineer. When changed, register the changed
setting and dates in the maintenance logbook accompanying the door.
WARNING
Do not wash, disassemble, rebuild or repair the sensor, otherwise
it may cause electric shock or breakdown of equipments.
Danger of electric shock.
SPECIFICATIONS
: OA-AXIS I / OA-AXIS II
Model
: Silver / Black
Cover color
: 2.0 (6'7") to 3.5m (11'5")
Mounting height
: See DETECTION AREA
Detection area
: Active Infrared Reflection
Detection method
: 1st to 3rd rows / -6 to +6
Depth angle adjustment
4th and 5th rows / +26 to +44
: 12 to 24VAC( 10%)
Power supply
12 to 30VDC( 10%)
: OA-AXIS I < 3VA
Power consumption
OA-AXIS II < 4VA
: Green / Stand-by
Operation LED
Blinking Red / 1st row detection
Red / 2nd row detection
Orange / 3rd to 5th rows detection
NOTE
The specifications herein are subject to change without prior notice due to improvements.
OUTER DIMENSIONS AND PART NAMES
267(10 1/2")
36(1 7/16")
(1) Connector
(2) Mounting holes
(3) Operation LED
(4) Depth angle adjustment screw
: OA-AXIS I /
Output
Form C relay
50V 0.3A Max.(Resistance load)
OA-AXIS II /
1st to 3rd rows / Form C relay
50V 0.3A Max. (Resistance load)
3rd to 5th rows / Form C relay
50V 0.3A Max.(Resistance load)
: Approx. 0.5 sec.
Output hold time
: <0.3 sec.
Response time
: -20 to +55 C(-4 to 131 F)
Operating temperature
: IP44
IP rate
: 320g (11.2oz)
Weight
: 1 Cable 3m (9'10")
Accessories
1 Operation manual
2 Mounting screws
1 Mounting template
1 Area adjustment tool
125(4 15/16")
45(1 3/4")
43(1 11/16")
[mm (inch)]
(8)
(5) Width adjustment screws
(6) Dipswitches
(7) Detection window
(8) Area adjustment tool
ENGLISH
DETECTION AREA
Motion / Presence
detection
Motion detection
Sensor setting
1st to 3rd rows
4th and 5th rows : +44
A
2.20(7'2 5/8")
B
0.14(5 1/2")
C
0.42(1'4 9/16")
D
0.82(2'8 5/16")
E
1.35(4'5 1/8")
F
1.90(6'2 13/16")
G
1.33(4'4 3/8")
H
2.05(6'8 11/16")
2.78(9'1 7/16")
I
The actual detection area may become smaller depending on the ambient light, the color / material of the
NOTE
object or the floor as well as the entry speed of the object.
*The values of the chart above is of the emitting spots, but not of the detection area.
INSTALLATION
NOTE
The following conditions are not suitable for the sensor installation.
-Fog or exhaust emission around the door.
-Wet floor
-Vibrating header or mounting surface.
-Moving objects or a heating radiator in the detection area.
-Highly reflecting floor or the presence of highly reflecting objects around the door.
1
1. Affix the mounting template at the desired mounting position.
2. Drill two mounting holes of ø3.4mm (ø1/8").
3. To pass the cable through to the header, drill a wiring hole of ø8mm (ø5/16").
4. Remove the mounting template.
5. Remove the housing cover. Attach the sensor to the mounting surface with two mounting screws.
Header
Sensor
Y
X
Door
Floor
Maximum mounting distance (Y)
X
0
50 (1 15/16")
100 (3 15/16")
150 (5 7/8")
200 (7 7/8")
250 (9 13/16")
300 (11 13/16")
CAUTION
Risk of getting caught.
NOTE
The sensor mounting position may be limited depending on the header thickness and the mounting height.
2
Wire the cable to the door controller properly as shown in the drawing below.
OA-AXIS I
OA-AXIS II
WARNING
Danger of electric shock.
3
1.Plug the connector of the sensor.
2.Supply power to the sensor. Adjust the detection area and set the dipswitches. (See ADJUSTMENTS)
Make sure to connect the cable correctly to the door controller before turning the power ON.
NOTE
To enable the presence detection, do not enter the detection area for 10 seconds after supplying the power.
4
Place the housing cover .
If wiring is to be exposed, break the knockout.
WARNING
Danger of electric shock.
A
1st row
2nd row
3rd row
4th row
5th row
G
G
H
: +6
I
2.50(8'2 7/16")
2.70(8'10 5/16")
0.16(6 5/16")
0.18(7 1/16")
0.48(1'6 7/8")
0.52(1'8 1/8")
0.93(3' 5/8")
1.00(3'3 3/8")
1.54(5' 5/8")
1.66(5'5 3/8")
2.17(7'1 7/16")
2.34(7'8 1/8")
1.51(4'11 7/16")
1.63(5'4 3/16")
2.32(7'7 5/16")
2.51(8'2 13/16")
3.15(10'4")
3.40(11'1 7/8")
.
MOUNTING TEMPLATE
H
H: Height from the floor to the bottom of the header
Y: Distance between the bottom of header and the sensor.
X: Distance between the door and the mounting surface
H
2,000 (6' 6")
2,200 (7' 2")
No limit
200 (7 7/8")
200 (7 7/8")
200 (7 7/8")
200 (7 7/8")
130 (5 1/8")
150 (5 7/8")
-
110 (4 5/16")
-
-
-
-
Make sure to affix the mounting template as described in the above chart.
Otherwise, it can be dangerous since there may be no presence detection area
around the threshold. Install the sensor as low as possible on the header.
Grey
Grey
White
Yellow
Green
Yellow
Green
White Str.
Yellow Str.
Green Str.
*The outputs from the 3rd row overlaps.
Before starting the procedure, ensure that the power is turned OFF.
When passing through the cable to the hole, make sure not to tear the shield,
otherwise it may cause electric shock or breakdown of the sensor.
Do not use the sensor without the cover.
When using the cable knockout, install the sensor indoors or use the rain-cover
(Separetely available) otherwise electric shock or breakdown of
the sensor may occur.
: Emitting spots
: Emitting spots
(Can be elminated)
: Detection area
B
C
D
E
F
[m(feet,inch)]
3.00(9'10 1/8")
3.50(11'5 13/16")
0.20(7 7/8")
0.23(9 1/16")
0.58(1'10 13/16")
0.67(2'2 3/8")
1.10(3'7 5/16")
1.30(4'3 3/16")
1.85(6' 13/16")
2.16(7'1 1/16")
2.60(8'6 3/8")
3.03(9'11 5/16")
1.81(5'11 1/4")
2.11(6'11 1/16")
2.79(9'1 13/16")
3.26(10'8 3/8")
3.79(12'5 3/16")
4.42(14'6")
[mm(feet,inch)]
2,500 (8' 2")
3,000 (9' 10")
200 (7 7/8")
200 (7 7/8")
200 (7 7/8")
200 (7 7/8")
170 (6 11/16")
200 (7 7/8")
130 (5 1/8")
150 (5 7/8")
-
120 (4 3/4")
-
-
Power supply
}
12 to 24VAC
10%
12 to 30VDC
10%
Common (COM.)
Normally open (N.O.)
Normally closed (N.C.)
Power supply
Grey
}
12 to 24VAC
10%
Grey
12 to 30VDC
10%
White
Common (COM.)
*
3rd to 5th
Normally open (N.O.)
rows output
Normally closed (N.C.)
*
Common (COM.)
1st to 3rd
Normally open (N.O.)
rows output
Normally closed (N.C.)

Advertisement

loading

Summary of Contents for Optex OA-AXIS I

  • Page 1 -Vibrating header or mounting surface. SPECIFICATIONS -Moving objects or a heating radiator in the detection area. -Highly reflecting floor or the presence of highly reflecting objects around the door. : OA-AXIS I / OA-AXIS II : OA-AXIS I / Model Output...
  • Page 2 Operation LED Green Blinking Red None Do not place any highly reflecting objects in the detection area, otherwise signal saturation may occur. OA-AXIS I Output REFERENCE Area depth adjustment with INFRARED FINDER (Separately available) Output from 1. Turn the depth adjustment screw to the right (Deep) to place the area most away from the door.

This manual is also suitable for:

Oa-axis ii