Connecting up
5.2 Wiring rules
5.2
Wiring rules
When wiring use cables with the following AWG categories or cross sections.
Wiring rules for ...
connectable cable cross sec-
tions for flexible cables ...
Stripped length of the cable
Wire end ferrule according to DIN 46228 with plastic ferrule**
* AWG: American Wire Gauge
** See note "Wire end ferrules"
Note
Wire end ferrules
Use crimp shapes with smooth surfaces, such as provided by square and trapeze shaped
crimp cross sections.
Crimp shapes with wave-shaped profile are unsuitable.
58
without wire end ferrule
with wire end ferrule with plastic
ferrule**
with wire end ferrule without plastic
ferrule**
with TWIN wire end ferrule**
Operating Instructions, 02/2018, C79000-G8976-C284-12
Screw/spring-loaded
terminals
0.25 - 2.5 mm
2
AWG: 24 - 13
0.25 - 2.5 mm
2
AWG: 24 - 13
0.25 - 2.5 mm
2
AWG: 24 - 13
0.5 - 1 mm
2
AWG: 20 - 17
8 - 10 mm
8 - 10 mm
SCALANCE X-200