4- INSTALLATION PROCEDURE:
Before to install the Dryer check if:
Wire diameter (gauge) complies with specifications (see table of item 2.1).
Supply voltage indicated by the label of Dryer Power Supply Cord is the same as the outlet where the
Appliance will be connected.
Will be appropriate Hot Air Exhausting
The installation condition:
There is a 10 cm minimum clearance between the Dryer and the walls.
Do not use electrical extension and/or electrical "T" sockets, as they can be sources of bad contact and
overloads in the mains.
The Dryer is well leveled, in order to prevent vibration and noise.
4.1 – Wire diameter (Gauge) for installation purposes:
voltage /
Distance from
the Circuit
Breaker
It's very important and necessary to install a ground wire if it is unavailable.
4.2 – Rack Installation:
There is a risk of death or injury if the installation instructions are not followed properly.
The security instructions mentioned below point out possible risks and advise the user how to reduce the
possibility of any injury and details what can happen if the instructions are not followed properly.
Before installing the Rack Set:
Check if the walls of Customer's home have the required structural conditions to have the Dryer's Rack Set
safely installed.
Check if the area where the rack will be installed is free of water, electricity and gas pipelines. For your
safety, please wear protective glove to handle the parts from the Rack Set and to lift the Dryer during
installation.
If the residence have walls made of wood or plaster, it is recommended that the installation of the dryer not
be done until you contact an exclusive representative of the material used for the walls and verify if the wall
material can take the weight of the dryer.
In case the dryer is installed in a wooden or plaster wall without the approval of the wall material
manufacturer, you will risk that the dryer might fall and void the warranty.
MSEX0110i – Wall Mounted Dryer WSI24ABBPH00
has good ventilation;
is not exposed to sunlight, heat sources or rain;
has a ground wire and the circuit breaker(s) is (are) installed.
2.5 mm
gauge
(12 AWG)
220 V
up to 70 meters 71 to116 meters
2
2
4.0 mm
(10 AWG)
2
6.0 mm
10.0 mm
(8 AWG)
(6 AWG)
--
--
2
Page 5 -21