Daikin SkyAir RZQ-P Series Service Manual page 168

Cooling only / heat pump
Hide thumbs Also See for SkyAir RZQ-P Series:
Table of Contents

Advertisement

Wiring Diagrams for Reference
FTQ18PAVJU
FTQ24PAVJU
X1M
POWER
SUPPLY
L1
L1
L2
L2
~
Z1C
208/230V
60Hz
N=5
GRN
/YLW
Q1 E1H F1UT
A1P
A2P
Q2 E2H F2UT
Q3 E3H F3UT
A
T1R
Q4 E4H F4UT
K1T K2T
K3M
K2M K1M
VIEW A
FRONT
ELECTRIC HEATER
ELECTRIC HEATER
(HKR-06,HKR-08C,HKR-10C)
L1
L1
L2
L2
NOTE ) 8
NOTE ) 8
POWER SUPPLY
POWER SUPPLY
Q1L
~
Q1L
~
208/230V
208/230V
BLK
BLK
60Hz
M2
M2
60Hz
K1T
K1T
M1
M1
Q1
Q1
Q2
E1H
E1H
E2H
F1UT
F1UT
F2UT
ELECTRIC HEATER (HKR-15C)
L1
L1
L2
L2
POWER SUPPLY
POWER SUPPLY
Q1L
~
~
208/230V
208/230V
BLK
60Hz
60Hz
M2
M4
M2
K1T
M1
M3
M1
Q1
Q2
Q3
E1H
E2H
E3H
F1UT
F2UT
F3UT
INDOOR UNIT
A1P
PRINTED CIRCUIT BOARD (MAIN)
A2P
PRINTED CIRCUIT BOARD (SUB)
FUSE ( T, 3.15A, 250V ) FOR ( A1P, A2P )
F1U
LIGHT EMITTING DIODE
HAP
( SERVICE MONITOR-GREEN )( A1P, A2P )
K1M
~
MAGNETIC RELAY
K3M
160
A1P
RED
BLU
NOTE) 7 T1R
X27A
RED X1 (240V)
X4
ORG
X2 (208V)
X5
BLK
BLU
X3 ( COM )
~
24V
1
2
X4M
BLU
Q1L Q2L
BLU
RED
RED
MS ~
M1F
X1A
GRY
9
5
YLW
9
5
M4
ORG
M3
5
9
AFTER INSTALLING OPTIONAL HEATER KIT,
.
MARK A "X" IN THE
MARK ACCORDING TO ELECTRIC HEATER KIT MODEL INSTALLED.
ELECTRIC HEATER (HKR-20C)
L1
L2
POWER SUPPLY
POWER SUPPLY
Q2L
Q1L
~
208/230V
208/230V
BLK
YLW
60Hz
M2
M4
K2T
K1T
M1
M3
Q1
Q2
E1H
E2H
F1UT
F2UT
K2R
MAGNETIC RELAY ( A2P )
~
MOTOR ( FAN )
M1F
PS
SWITCHING POWER SUPPLY (A1P)
R1T
THERMISTOR ( LIQUID )
R2T
THERMISTOR ( GAS )
TRANSFORMER 208V/24V, 240V/24V
T1R
X1A~X3A
CONNECTOR
R1T R2T
GRN
X18A X17A X15A
F1U
PS
HAP
X35A
X70A
X7A
X3A
M
Y1E
WHT
A2P
X10A
X15A X16A
X1A
F1U
ORG
K3M
1
BLK
3
K2M
RED
2
BLU
X4A
X5A
K1M
4
1
2
1
3
13
14
13
14 13
K1M
K2M
NOTE) 6
ELECTRIC HEATER
L1
( 3 AND 4 ROW ELEMENT )
L2
NOTES)
1.
Q2L
~
2. IN CASE USING CENTRALIZED REMOTE CONTROLLER,CONNECT IT TO THE UNIT
YLW
IN ACCORDANCE WITH THE ATTACHED INSTALLATION MANUAL.
60Hz
M2
M4
3. WHEN CONNECTING THE INPUT WIRES FROM OUTSIDE, FORCED OFF OR ON/OFF
K2T
M1
M3
CONTROL OPERATION CAN BE SELECTED BY REMOTE CONTROLLER.
IN DETAILS, REFER TO THE INSTALLATION MANUAL ATTACHED THE UNIT.
4. COLORS PNK: PINK WHT: WHITE YLW: YELLOW ORG: ORANGE BLU: BLUE
Q3
Q4
BLK: BLACK RED: RED BRN: BROWN GRY: GRAY GRN: GREEN
5. USE COPPER CONDUCTORS ONLY.
E3H
E4H
6. WHEN INSTALL AN ELECTRIC HEATER.DON'T SHARE THE POWER SUPPLY OF
THE ELECTRIC HEATER WITH THAT OF THE INDOOR UNIT.
F3UT
F4UT
USE THE STANDARD OPTIONAL ELECTRIC HEATER.
7. RED WIRE TO BE ON X1 FOR 230V AND ON X2 FOR 208V.
8. IN CASE INSTALL HKR-03 OR HKR-06,THERE IS NO CIRCUIT BREAKER.
TERMINAL STRIP ( POWER SUPPLY )
X1M
TERMINAL STRIP (CONTROL )
X2M
TERMINAL STRIP (CONTROL )
X3M
TERMINAL STRIP ( POWER SUPPLY )
X4M
Y1E
ELECTRONIC EXPANSION VALVE
NOISE FILTER ( FERRITE CORE )
Z1C
WIRED REMOTE CONTROLLER
THERMISTOR ( AIR )
R1T
X2M
INPUT FROM OUTSIDE
T2
T1
NOTE)3
WHT
F2
TRANSMISSION WIRING
F1
CENTRALIZED REMOTE
PNK
P2
WHT
CONTROLLER NOTE ) 2
P1
YLW
ORG
X30A
SS1
P2
R1T
P1
BLU
WIRED REMOTE
BLK
CONTROLLER
(OPTIONAL ACCESSORY)
X3M
PNK
10
WHT
INPUT
9
YLW
8
INPUT
ORG
7
BLU
6
BLK
INPUT
5
RED
4
BRN
OUTPUT
3
GRY
2
OUTPUT
WHT
1
X25A
X11A
X12A
HAP
X7A
X8A
X23A
4
1
2
1
2
1
3
4
2
2
14
K3M
4
6
5
X2A
NOTE) 6
K1T
K1T
K2T
ELECTRIC HEATER
( 1 AND 2 ROW ELEMENT )
:FIELD WIRING,:
TERMINAL
,
: CONNECTOR, :
TERMINAL BLOCK
: PROTECTIVE GROUND ( SCREW ) , :
NOISELESS GROUND
SELECTOR SWITCH ( MAIN/SUB )
SS1
ELECTRIC HEATER
E1H~E4H
ELECTRIC HEATER
TEMPERATURE FUSE ( 199.4°F )
F1UT~F4UT
TIME DELAY RELAY
K1T, K2T
Q1~Q4
THERMAL LIMIT
Q1L, Q2L
CIRCUIT BREAKERS
SiUS28-902_B
3D065036F
Appendix

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents