Water
Water is used in the cooling system in order to
transfer heat.
Distilled water or deionized water is
recommended for use in engine cooling systems.
DO NOT use the following types of water in cooling
systems: Hard water, softened water that has been
conditioned with salt, and sea water.
If distilled water or deionized water is not available,
use water with the properties that are listed in Table 5.
Table 5
Acceptable Water
Property
Chloride (Cl)
Sulfate (SO
)
4
Total Hardness
Total Solids
Acidity
For a water analysis, consult one of the following
sources:
Local water utility company
Agricultural agent
Independent laboratory
Additives
Additives help to protect the metal surfaces of
the cooling system. A lack of coolant additives or
insufficient amounts of additives enable the following
conditions to occur:
Corrosion
Formation of mineral deposits
Rust
Scale
Foaming of the coolant
Many additives are depleted during engine operation.
These additives must be replaced periodically.
Additives must be added at the correct concentration.
Overconcentration of additives can cause the
inhibitors to drop out-of-solution. The deposits can
enable the following problems to occur:
Maximum Limit
40 mg/L
100 mg/L
170 mg/L
340 mg/L
pH of 5.5 to 9.0
Formation of gel compounds
Reduction of heat transfer
Leakage of the water pump seal
Plugging of radiators, coolers, and small passages
Glycol
Glycol in the coolant helps to provide protection
against the following conditions:
Boiling
Freezing
Cavitation of the water pump
For optimum performance, Perkins recommends a
1:1 mixture of a water/glycol solution.
Note: Use a mixture that will provide protection
against the lowest ambient temperature.
Note: 100 percent pure glycol will freeze at a
temperature of −23 °C (−9 °F).
Most conventional antifreezes use ethylene glycol.
Propylene glycol may also be used. In a 1:1 mixture
with water, ethylene and propylene glycol provide
similar protection against freezing and boiling. See
Tables 6 and 7.
Table 6
Ethylene Glycol
Concentration
Protection
50 Percent
−36 °C (−33 °F)
60 Percent
−51 °C (−60 °F)
NOTICE
Do not use propylene glycol in concentrations that ex-
ceed 50 percent glycol because of propylene glycol's
reduced heat transfer capability. Use ethylene glycol
in conditions that require additional protection against
boiling or freezing.
Table 7
Propylene Glycol
Freeze
Concentration
Protection
50 Percent
−29 °C (−20 °F)
To check the concentration of glycol in the coolant,
measure the specific gravity of the coolant.
Maintenance Section
Refill Capacities
Freeze
Boil
Protection
106 °C (223 °F)
111 °C (232 °F)
Anti-Boil
Protection
106 °C (223 °F)
39