button to complete the configuration. The module will re-initialize with the
changed configuration.
(N) Upload
Upload the firmware through the network.
After upload
(O) Exit
Close the configuration Tool program.
(P) Serial Configuration
Serial information of selected EG-SR-7100A is displayed.
(Q) Inactivity time
After the connection is established, if there is not data transmission within
the time defined in Inactivity time, the connection is closed automatically.
(R) Data Packing Condition
You can designate how the serial data can be packed to be sent to the
Ethernet. There are 3 delimiters - time, size and character. If all of them are
set as '0', whenever the serial data is arrived, they are sent to the Ethernet.
A.
Time: Every designated time, serial data converted to Ethernet.
B.
Size: Every designated data size, serial data converted to Ethernet.
C.
Char: Every designated character, serial data converted to Ethernet. (It's
When any of three delimiters is satisfied, data can be sent to the Ethernet.
Ex) Delimiter: Size=10, Char=0x0D
Serial data : 0123456789abc
Ethernet data : 0123456789
"abc" data remains in the serial buffer of module