Physical And Operating Environment; Temperature And Humidity; Reliability; Dimensions And Weight - NCR RealPOS 7199 User Manual

Thermal receipt station printer
Hide thumbs Also See for RealPOS 7199:
Table of Contents

Advertisement

A-130

Physical and Operating Environment

Temperature and Humidity

Operating
Storage
Transit
Condensation

Reliability

The numbers in the table refer to the Mean Cycle Between Failure (MCBF) for the items
indicated.
Note: Reliability statistics are based on averages exhibited under lab conditions and do
not constitute a warranty.
Component
Thermal Mechanism
Communications Card (RS232/USB) 43.45 Million Hours
Communications Card (LAN)
Main PCB
Knife

Dimensions and Weight

Height
Width
Depth
Weight
Temperature
5 to 50°C (41 to 122°F)
–10 to 55°C (14 to 131°F)
–40 to 60°C (–40 to 140°F)
Condensation may occur when the printer is moved
from cold to warm areas after shipment. The printer's
design permits operation after drying out and stabilizing
at room temperature.
130.0 mm (5.12 in.)
125.8 mm (4.95 in.)
163.0 mm (6.42 in.)
1.1 kg (2.42 lbs)
Humidity
5% to 90%
10% to 90%
5% to 95%
Reliability
60 Million Lines
26.3 Million Hours
1.65 Million Hours
2 Million Cuts
Printer Specifications