Model Nomenclature - Daikin Enfinity CCW Installation And Maintenance Manual

Horizontal water source heat pumps
Table of Contents

Advertisement

Category
Product Category
Product Identifier
Design Series (Vintage)
Nominal Capacity
Controls
Voltage
Return Air
Discharge Air
Blower Motor
Construction Type
Heat Exchanger
Drain Pan
Refrigerant
Cabinet Electrical
Color
Agency Listing
Packaging
Product Style
Notes: * A 460 volt, 3-phase unit that utilize an ECM fan motor will need a 4-wire WYE voltage supply with 3 hot leads and a neutral wire. To power the EC motor with
neutral and one hot for 277/60/1 voltage to the EC motor.
IM 1049-9
Code Item
Code Option
01
1
02
2-4
03
5
04
6-8
05
9
06
10
08
12
09
13
10
14-15
12
18
13
19
19
30-32
20
33
22
35-37
24
39
26
41
27
42
29
44
Code Designation & Description
W
=
Water Source Heat Pump
CCH =
R410A, Ceiling-Mounted, Standard Range
CCW =
R410A, Ceiling-Mounted, Geothermal Range
4
=
D Design
5
=
E Design
007
=
7,000 Btuh Nominal Cooling
009
=
9,000 Btuh Nominal Cooling
012
=
12,000 Btuh Nominal Cooling
015
=
15,000 Btuh Nominal Cooling
019
=
19,000 Btuh Nominal Cooling
024
=
24,000 Btuh Nominal Cooling
030
=
30,000 Btuh Nominal Cooling
036
=
36,000 Btuh Nominal Cooling
042
=
42,000 Btuh Nominal Cooling
048
=
48,000 Btuh Nominal Cooling
060
=
60,000 Btuh Nominal Cooling
070
=
70,000 Btuh Nominal Cooling
B
=
MicroTech® III Unit Controller
C
=
MicroTech III Unit Controller w/L
D
=
MicroTech III Unit Controller w/BACnet® Communication Module
A
=
115-60-1 (Sizes 007- 009 only)
E
=
208-230/60/1
J
=
265/277-60-1
F
=
208-230/60/3
K
=
460/60/3*
L
=
575/60/3
M
=
230/50/1
N
=
380/50/3
L
=
Left
R
=
Right
E
=
End Discharge
S
=
Straight Discharge
01
=
Standard PSC
03
=
Low Static
04
=
ECM
A
= Standard (1/2 inch FG insulation /1" filter rack)
B
=
Standard with 2" Filter Rack
C
=
Standard with Compressor Sound Blanket
D
= Standard with Compressor Sound Blanket and 2" filter rack
E
=
Indoor Air Quality (IAQ) - Closed Cell Insulation
F
=
IAQ with 2" Filter Rack
G
=
IAQ with Compressor Sound Blanket
H
=
IAQ with Compressor Sound Blanket and 2" Filter Rack
J
=
Sound Package
K
=
Sound Package w/2" Filter Rack
C
=
Copper Inner Tube - Steel Outer Tube
S
=
Cupronickel Inner Tube - Steel Outer Tube
YYY =
Standard (High Density Polyethylene) HDPE Drain Pan
SYY =
Stainless Steel Drain Pan
A
=
R410A
YYY =
Standard (50VA Transformer)
75VA =
75VA Control Transformer
Y
=
None (Galvanized)
C
=
ETL, CETL, ARI, MEA
1
=
Standard
1
=
Style
4
M
n
odel
oMenClature
W
® Communication Module
on
orks
www.DaikinApplied.com

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

Enfinity cch

Table of Contents