Model Nomenclature - Daikin Enfinity VFC Installation And Maintenance Manual

Enfinity vertical water source heat pumps
Table of Contents

Advertisement

Category
Product Category
Product Identifier
Design Series (Vintage)
Nominal Capacity
Controls
Voltage
Return Air
Discharge Air
Blower Motor
Construction Type
Heating Options
Dehumidification
Desuperheater
Refrigerant
Cabinet Electrical
Water Flow Control
Color
Notes: * A 460 volt, 3-phase unit that utilize an ECM fan motor will need a 4-wire WYE voltage supply with 3 hot leads and
a neutral wire. To power the ECM motor with neutral and one hot for 277/60/1 voltage to the ECM motor.
IM 930-6 • Enfinity Vertical Water Source Heat Pumps
Code Item
Code Option
01
1
02
2-4
03
5
04
6-8
05
9
06
10
08
12
09
13
10
14-15
12
18
14
20
15
21-22
19
30-32
20
33
22
35-37
23
38
24
39
Code Designation & Description
W
= Water Source Heat Pump
VFC = R410A, Floor Mounted, Standard Range
VFW = R410A, Floor Mounted, Geothermal Range
1
= A Design
2
= B Design
3
= C Design
4
= D Design
009 = 9,000 Btuh Nominal Cooling
012 = 12,000 Btuh Nominal Cooling
015 = 15,000 Btuh Nominal Cooling
019 = 19,000 Btuh Nominal Cooling
024 = 24,000 Btuh Nominal Cooling
030 = 30,000 Btuh Nominal Cooling
036 = 36,000 Btuh Nominal Cooling
042 = 42,000 Btuh Nominal Cooling
048 = 48,000 Btuh Nominal Cooling
060 = 60,000 Btuh Nominal Cooling
070 = 70,000 Btuh Nominal Cooling
B
=
MicroTech® III Unit Controller
C
=
MicroTech III Unit Controller w/L
D
=
MicroTech III Unit Controller w/BACnet® Communication Module
F
= Microtech III Unit Controller w/BACnet Comm Module - WSHP System
A
=
115-60-1 (Sizes 007-012 only)
E
= 208-230/60/1
J
= 265/277-60-1
F
= 208-230/60/3
K
= 460/60/3*
L
= 575/60/3
L
= Left
R
= Right
T
= Top
04
= ECM
B
= Standard w/2" Filter Rack
C
= Standard w/Compressor Sound Blanket
D
= Standard w/Compressor Sound Blanket and 2" Filter Rack
F
= Indoor Air Quality (IAQ) w/2" Filter Rack
G
= Indoor Air Quality (IAQ) w/Compressor Sound Blanket
H
= Indoor Air Quality (IAQ) w/Compressor Sound Blanket and 2" Filter Rack
A
= 5.0 kW Electric Heat
B
= 10.0 kW Electric Heat
AA
= Hot Gas Reheat Coil
DSH = Desuperheater
A
= R410A
75VA = 75VA Control Transformer
C
= 2-Way Motorized 1/2" Isolation Valve, General Close-Off Pressure N.C.
V
= 2-Way Motorized 1/2" Isolation Valve, General Close-Off Pressure N.O.
H
= 2-Way Motorized 1/2" Isolation Valve, High Close-Off Pressure N.C.
D
= 2-Way Motorized 3/4" Isolation Valve, General Close-Off Pressure N.C.
K
= 2-Way Motorized 3/4" Isolation Valve, General Close-Off Pressure N.O.
J
= 2-Way Motorized 3/4" Isolation Valve, High Close-Off Pressure N.C.
A
= Antique Ivory Pre-Paint
Y
= None
4
M
n
odel
oMenClature
W
® Communication Module
on
orks
www.DaikinApplied.com

Hide quick links: