Daikin Altherma EHVH08S18CBV Installation Manual
Daikin Altherma EHVH08S18CBV Installation Manual

Daikin Altherma EHVH08S18CBV Installation Manual

Hide thumbs Also See for Altherma EHVH08S18CBV:
Table of Contents

Advertisement

Quick Links

Installation manual
Daikin Altherma – Low temperature split
EHVH04S18CBV
EHVH08S18CBV
EHVH08S26CBV
Installation manual
EHVH11S26CBV
English
Daikin Altherma – Low temperature split
EHVH16S26CBV

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the Altherma EHVH08S18CBV and is the answer not in the manual?

Questions and answers

Subscribe to Our Youtube Channel

Summary of Contents for Daikin Altherma EHVH08S18CBV

  • Page 1 Installation manual Daikin Altherma – Low temperature split EHVH04S18CBV EHVH08S18CBV EHVH08S26CBV Installation manual EHVH11S26CBV English Daikin Altherma – Low temperature split EHVH16S26CBV...
  • Page 2 3P459951-3...
  • Page 3: Table Of Contents

    5.2.2 Quick wizard: Standard..........13 Daikin website (publicly accessible). 5.2.3 Quick wizard: Options ..........13 ▪ The full set of latest technical data is available on the Daikin 5.2.4 Quick wizard: Capacities (energy metering) ....14 extranet (authentication required). 5.2.5 Space heating control ..........
  • Page 4: About The Box

    See the recommended procedure as described in "6.2  Checklist 2 screws for fixing the user interface. during commissioning" on page 18. 7 Reinstall the top panel and the front plate. Installation manual EHVH04+08S18CBV + EHVH08~16S26CBV Daikin Altherma – Low temperature split 4P449977-1B – 2018.02...
  • Page 5: Preparing Electrical Wiring

    500 m. Applicable for both single user interface and dual user interface connection. NOTICE More technical specifications of the different connections are indicated on the inside of the indoor unit. 4× EHVH04+08S18CBV + EHVH08~16S26CBV Installation manual Daikin Altherma – Low temperature split 4P449977-1B – 2018.02...
  • Page 6: Mounting The Indoor Unit

    4.4.2 To connect the recirculation piping Prerequisite: Only required if you need recirculation in your system. Installation manual EHVH04+08S18CBV + EHVH08~16S26CBV Daikin Altherma – Low temperature split 4P449977-1B – 2018.02...
  • Page 7: To Fill The Water Circuit

    1 Connect the water supply hose to the fill valve. 3 Routing of the wiring inside the unit should be as follows: 2 Open the fill valve. EHVH04+08S18CBV + EHVH08~16S26CBV Installation manual Daikin Altherma – Low temperature split 4P449977-1B – 2018.02...
  • Page 8: To Connect The Main Power Supply

    It is only possible for the system to have EITHER preferential kWh rate power supply OR a safety CAUTION thermostat. Do NOT push or place redundant cable length in the unit. Installation manual EHVH04+08S18CBV + EHVH08~16S26CBV Daikin Altherma – Low temperature split 4P449977-1B – 2018.02...
  • Page 9: To Connect The User Interface

    Be careful NOT to pinch the wiring when attaching the frontplate to the unit. The main user interface is required for operation, but has to be ordered separately (mandatory option). EHVH04+08S18CBV + EHVH08~16S26CBV Installation manual Daikin Altherma – Low temperature split 4P449977-1B – 2018.02...
  • Page 10: To Connect The Domestic Hot Water Pump

    To connect the safety thermostat (normal closed contact) 1 Connect the safety thermostat (normal closed) cable to the appropriate terminals as shown in the illustration below. Installation manual EHVH04+08S18CBV + EHVH08~16S26CBV Daikin Altherma – Low temperature split 4P449977-1B – 2018.02...
  • Page 11: To Connect The Anti-Legionella Heater Power Supply

    If you do NOT configure the system correctly, it might NOT work as expected. The configuration influences the following: EHVH04+08S18CBV + EHVH08~16S26CBV Installation manual Daikin Altherma – Low temperature split 4P449977-1B – 2018.02...
  • Page 12: To Access The Most Used Commands

    1 Press for more than 4 seconds. Result: The user permission level switches to End user. The user interface will return to the default home screen. Installation manual EHVH04+08S18CBV + EHVH08~16S26CBV Daikin Altherma – Low temperature split 4P449977-1B – 2018.02...
  • Page 13: Quick Wizard: Standard

    Domestic hot water settings INFORMATION If there is no optional backup heater installed, you must set [E‑05] to 1. Otherwise an error code (UA-17) will occur. EHVH04+08S18CBV + EHVH08~16S26CBV Installation manual Daikin Altherma – Low temperature split 4P449977-1B – 2018.02...
  • Page 14: Quick Wizard: Capacities (Energy Metering)

    + scheduled (only for [C-09] Alarm No alarm No power leaving water temperature control) supply to unit 0 (default) Closed output Open output Open output Open output Closed output Installation manual EHVH04+08S18CBV + EHVH08~16S26CBV Daikin Altherma – Low temperature split 4P449977-1B – 2018.02...
  • Page 15 This setting can compensate for a slow or a quick heating system by adjusting the unit capacity during the heat up cycle. EHVH04+08S18CBV + EHVH08~16S26CBV Installation manual Daikin Altherma – Low temperature split 4P449977-1B – 2018.02...
  • Page 16: Domestic Hot Water Control

    The maximum temperature that users can select for the domestic hot water. You can use this setting to limit the temperature at the hot water taps. Installation manual EHVH04+08S18CBV + EHVH08~16S26CBV Daikin Altherma – Low temperature split 4P449977-1B – 2018.02...
  • Page 17: Menu Structure: Overview Installer Settings

    Depending on the selected installer settings and unit type, settings will be visible/invisible. INFORMATION Anti-legionella heater. In the menu structure the term "Booster heater" is used. However, this is actually an anti- legionella heater. EHVH04+08S18CBV + EHVH08~16S26CBV Installation manual Daikin Altherma – Low temperature split 4P449977-1B – 2018.02...
  • Page 18: Commissioning

    See "To check the water volume" in page are turned OFF. "3.2 Preparing water piping" on page 4. Installation manual EHVH04+08S18CBV + EHVH08~16S26CBV Daikin Altherma – Low temperature split 4P449977-1B – 2018.02...
  • Page 19: To Perform A Test Run

    ▪ Backup heater (step 2) test ▪ Fill in the installer setting table (in the operation manual) with the ▪ Pump test actual settings. EHVH04+08S18CBV + EHVH08~16S26CBV Installation manual Daikin Altherma – Low temperature split 4P449977-1B – 2018.02...
  • Page 20: Technical Data

    ▪ Explain the user about energy saving tips as described in the operation manual. Technical data A subset of the latest technical data is available on the regional Daikin website (publicly accessible). The full set of latest technical data is available on the Daikin extranet (authentication required). Piping diagram: Indoor unit...
  • Page 21 Domestic hot water pump For safety thermostat For safety thermostat Shut-off valve Inrush Inrush current (*) 3-way valve for floor heating/domestic hot Max. load Maximum load water EHVH04+08S18CBV + EHVH08~16S26CBV Installation manual Daikin Altherma – Low temperature split 4P449977-1B – 2018.02...
  • Page 22 For wired thermostat For wired thermostat Max. load Maximum load For wireless thermostat For wireless thermostat Min. load Minimum load Main LWT zone Main leaving water temperature zone Installation manual EHVH04+08S18CBV + EHVH08~16S26CBV Daikin Altherma – Low temperature split 4P449977-1B – 2018.02...
  • Page 23 4 A2P: P1-P2 user interface X5M: 1-2 230 V communication Only for *KRUCBL* Optional part 2 core 2x0.75 communication A2P: P1-P2 user interface 4D106404-1 EHVH04+08S18CBV + EHVH08~16S26CBV Installation manual Daikin Altherma – Low temperature split 4P449977-1B – 2018.02...
  • Page 24 4P449977-1 B 0000000B 4P449977-1B 2018.02...