Siemens SINAMICS DCM Operating Instructions Manual page 29

Commutation reactors
Hide thumbs Also See for SINAMICS DCM:
Table of Contents

Advertisement

Table 6- 2
Commutating reactors 3ph
uk=4 % for rated current and 3AC 480 V/50 Hz or 3AC 575 V/60 Hz
Order
AC rated
number
current
6RX1800-..
4FK00
13 A
4FK01
25 A
4FK02
51 A
4FK03
76 A
4FK04
106 A
4FK05
174 A
4FK06
232 A
4FK07
332 A
4FK08
374 A
4FK10
498 A
4FK11
664 A
4FK12
706 A
4FK13
913 A
4FK14
996 A
4FK15
1328 A
4FK16
1660 A
4FK17
1326 A
4FK18
2324 A
SINAMICS DCM commutating reactors
Operating Instructions, 11/2013, A5E32621741B
DC rated
Inductance Copper
current
losses
15 A
2.779 mH 27.4 W
30 A
1.389 mH 34.8 W
60 A
0.695 mH 42.3 W
90 A
0.463 mH 56.3 W
125 A
0.333 mH 68.8 W
210 A
0.202 mH 204.6 W
280 A
0.152 mH 178.3 W
400 A
0.106 mH 193.7 W
450 A
0.094 mH 189.1 W
600 A
0.071 mH 313.8 W
800 A
0.053 mH 255.6 W
850 A
0.050 mH 293.9 W
1100 A
0.039 mH 375.6 W
1200 A
0.035 mH 332.7 W
1600 A
0.027 mH 320.4 W
2000 A
0.021 mH 436.5 W
2200 A
0.019 mH 464.7 W
2800 A
0.015 mH 671.8 W
Total
SCCR
Weight
losses
39.2 W
2.0 kA
2.9 kg
(20 ms)
57.8 W
5.0 kA
6.0 kg
(20 ms)
77.2 W
6.5 kA
11.8 kg
(100 ms)
118.0 W
9.0 kA
16.3 kg
(100 ms)
152.9 W
15 kA
22.3 kg
(100 ms)
255.6 W
15 kA
26.0 kg
(100 ms)
231.4 W
20 kA
37.8 kg
(100 ms)
261.5 W
24 kA
56.1 kg
(100 ms)
279.2 W
24 kA
56.8 kg
(100 ms)
396.9 W
35 kA
78.1 kg
(200 ms)
360.8 W
75 kA
96.6 kg
(200 ms)
404.1 W
75 kA
96.6 kg
(200 ms)
558.6 W
75 kA
114.5 kg
(200 ms)
532.8 W
75 kA
127.8 kg
(200 ms)
573.7 W
75 kA
177.6 kg
(200 ms)
819.0 W
75 kA
161.0 kg
(200 ms)
819.9 W
75 kA
164.2 kg
(200 ms)
1056.7 W
75 kA
258.2 kg
(200 ms)
Technical data
Rated
Insulating
insulating
material
voltage
class
according
to
DIN EN
60085
600 V
B
600 V
B
600 V
B
600 V
B
600 V
B
600 V
F
600 V
F
600 V
F
600 V
F
1000 V
F
1000 V
F
1000 V
F
1000 V
F
1000 V
F
1000 V
F
1000 V
F
1000 V
F
1000 V
F
29

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents