Siemens SINAMICS DCM Operating Instructions Manual page 28

Commutation reactors
Hide thumbs Also See for SINAMICS DCM:
Table of Contents

Advertisement

Technical data
Specific technical data
Dimensions, see Section Dimension drawings (Page 33).
3-phase commutating reactors
Table 6- 1
Commutating reactors 3ph
uk=4 % for rated current and 3AC 400 V/50 Hz or 3AC 480 V/60 Hz
Order
AC rated
number
current
6RX1800-..
4DK00
13 A
4DK01
25 A
4DK02
51 A
4DK03
76 A
4DK04
106 A
4DK05
174 A
4DK06
232 A
4DK07
332 A
4DK08
374 A
4DK10
498 A
4DK11
706 A
4DK12
996 A
4DK13
1328 A
4DK14
1660 A
4DK15
2490 A
28
DC rated
Inductance Copper
current
losses
15 A
2.315 mH 22.8 W
30 A
1.158 mH 30.8 W
60 A
0.579 mH 43.5 W
90 A
0.386 mH 64.4 W
125 A
0.278 mH 51.3 W
210 A
0.169 mH 164.8 W
280 A
0.127 mH 197.4 W
400 A
0.089 mH 190.7 W
450 A
0.079 mH 186.7 W
600 A
0.059 mH 277.0 W
850 A
0.042 mH 329.4 W
1200 A
0.030 mH 390.3 W
1600 A
0.022 mH 339.3 W
2000 A
0.018 mH 369.3 W
3000 A
0.012 mH 587.3 W
Total
SCCR
Weight
losses
33.1 W
2.0 kA
2.9 kg
(20 ms)
53.2 W
5.0 kA
4.4 kg
(20 ms)
73.2 W
6.5 kA
10.9 kg
(100 ms)
118.5 W
9.0 kA
13.8 kg
(100 ms)
119.3 W
15 kA
23.9 kg
(100 ms)
206.4 W
15 kA
24.0 kg
(100 ms)
256.2 W
20 kA
26.8 kg
(100 ms)
251.1 W
24 kA
45.8 kg
(200 ms)
251.7 W
24 kA
56.8 kg
(200 ms)
357.4 W
35 kA
60.0 kg
(200 ms)
424.8 W
55 kA
81.6 kg
(200 ms)
562.8 W
75 kA
100.1 kg
(200 ms)
554.5 W
75 kA
138.8 kg
(200 ms)
591.9 W
75 kA
210.7 kg
(200 ms)
1038.3 W
75 kA
205.6 kg
(200 ms)
Operating Instructions, 11/2013, A5E32621741B
Rated
Insulating
insulating
material
voltage
class
according
to
DIN EN
60085
600 V
B
600 V
B
600 V
B
600 V
B
600 V
B
600 V
F
600 V
F
600 V
F
600 V
F
600 V
F
1000 V
F
1000 V
F
1000 V
F
1000 V
F
1000 V
F
SINAMICS DCM commutating reactors

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents