Inserting the needle seals
1.
WARNING!
Risk of injury through the use of incorrect spare parts!
Insert the slotted ring ( Fig. 17/1) into the bracket ( Fig. 17/2). Here, make sure that the
slotted ring ( Fig. 18/1) is in the correct position.
2.
Make sure that the O-ring ( Fig. 17/3) fits correctly on the clamping screw ( Fig. 17/4).
Ensure that the slotted ring ( Fig. 17/5) is correctly positioned in the clamping screw (
Fig. 17/4).
Fig. 18: Installation state
3.
Place the bracket ( Fig. 17/2) with the slotted ring ( Fig. 17/1) onto the material needle and
then slide it into the main element.
4.
Screw in the bracket with the socket wrench until you feel gentle resistance.
5.
Press the material needle with the material nozzle firmly into the main element ( Fig. 17/6).
6.
Tighten the complete package with the socket wrench.