The connections are marked with letter abbreviations.
Fig. 7: Connecting the automatic spray gun
1.
Connect control air "OPEN" to "ST A" ( Fig. 7).
2.
Connect control air "CLOSED" to "ST Z" ( Fig. 7) (optional, only for double controller
design).
For extremely short switching times, the automatic spray gun can also be connected
pneumatically via the optional connection "ST Z" (
trol' on page 23).
3.
Connecting the atomising air:
n
Connect connection round jet to "R" ( Fig. 7).
n
Connect connection flat jet to "F" ( Fig. 7).
4.
Connect fluid supply to input "M↑" ( Fig. 7).
5.
For design with circulation connection, connect the fluid circulation line to output "M↓" (
Fig. 7).
The fluid connections "M↑" and "M↓" ( Fig. 7) are marked with arrows and may not be
interchanged.
GB–22
Operating instructions
Ä Chapter 6.8 'Preliminary air con-
T-Dok-449-GB-Rev.7
mail@krautzberger.com, www.krautzberger.com