RTLC40/FASTRACK : FASTRACK and scale application
6
Slide RTLC scale into the FASTRACK ensuring the
scale is fed under the projections as shown.
Scale can be installed manually by either pulling or
pushing it through the FASTRACK carrier.
Alternatively use the optional
scale installation tool
(A-9589-0420) as shown,
for easy installation.
7
Optional: fix self-adhesive end covers
ensuring a gap of at least 1 mm between
the end of the scale and the end cover
Ensure a gap
>1 mm
8
Clean FASTRACK and scale
using a lint-free cloth
QUANTiC linear installation guide
NOTE: For instructions on how to use the
scale installation tool, download 'User guide
– RTL* scale installation tool
(A-9589-0420)
from the website at
www.renishaw.com/encoderinstallationguides.
Projections
IMPORTANT: If manually installing
the scale using fingers, suitable
gloves should be worn to protect
against injury from sharp edges.
RTLC40/FASTRACK : Scale datum
(Continued)
The datum clamp fixes the RTLC40 scale rigidly to the substrate at the location chosen.
The metrology of the system may be compromised if the datum clamp is not used.
The datum clamp does not need to be fitted adjacent to a reference mark.
It can be positioned anywhere along the axis depending upon the customer's requirements.
Mechanical clamp
15 ±1
'
25
3
Additional screws available (Pack of 25 A-9584-2047)
Adhesive clamp
Using dispensing tip P-TL50-0209 apply Loctite 435
between scale and FASTRACK so it wicks underneath
adjacent to user selected datum location as shown.
NOTE: Drawing shows the scale datum adjacent
to the chosen reference mark.
NOTE: Only apply Loctite 435 in
these gaps to ensure best bond.
Loctite 435 will wick under the
scale to lock it to the substrate.
Reference mark
selector magnet
IN-TRAC reference mark
Do not place clamp tip
over shaded area
RTLC40 clamp
(A-9589-0077)
12
M3 x 6 low head screw,
supplied with clamp
2.3
1.7
5 min
12
thread
depth
16
NOTE: When reference mark and
datum clamp aligned as shown,
reference output will be positionally
repeatable with respect to substrate.
8