Readhead Mounting And Alignment - Renishaw QUANTiC RTLC40-S Installation Manual

Linear encoder system
Hide thumbs Also See for QUANTiC RTLC40-S:
Table of Contents

Advertisement

Readhead mounting and alignment

Mounting brackets
The bracket must have a flat mounting surface and should provide adjustment to enable conformance to the
installation tolerances, allow adjustment to the rideheight of the readhead, and be sufficiently stiff to prevent
deflection or vibration of the readhead during operation.
Readhead set-up
Ensure that the scale, readhead optical window and mounting face are clean and free from obstructions.
NOTE: When cleaning readhead and scale apply cleaning fluid sparingly, do not soak.
To set nominal rideheight, place the appropriate spacer with the aperture under the optical centre of the readhead
to allow normal LED function during set-up procedure. RTLC40-S: green spacer, RTLC40/FASTRACK: black spacer.
Adjust the readhead to achieve a flashing Green LED along the full axis of travel. The faster the flash rate,
the closer it is to optimum set-up. The optional Advanced Diagnostic Tool ADTi-100 (A-6195-0100) and
ADT View software can be used to optimise signal strength in challenging installations.
See www.renishaw.com/adt for more information.
NOTE: When re-installing the readhead factory defaults should be restored,
QUANTiC readhead and RTLC40-S
Pitch
0° ±1°
QUANTiC linear installation guide
see page
12.
Yaw
0° ±0.9°
Readhead set-up LED status
Roll
0° ±0.8°
IMPORTANT:
Use green spacer
with RTLC-S
Rideheight
2.1 ± 0.2 mm
Readhead LED diagnostics
Mode
Installation mode
Calibration mode
Normal operation
Alarm
QUANTiC readhead and RTLC40 /FASTRACK
Green
Orange
Red
flashing
flashing
flashing
IMPORTANT:
Use black spacer with
RTLC/FASTRACK
LED
Green flashing
Good set-up, maximise flash rate for optimum set-up
Orange flashing
Poor set-up, adjust readhead to obtain Green flashing LED
Red flashing
Poor set-up, adjust readhead to obtain Green flashing LED
Blue single flashing
Calibrating incremental signals
Blue double flashing
Calibrating reference mark
Blue
AGC on, optimum set-up
Green
AGC off, optimum set-up
Red
Poor set-up; signal may be too low for reliable operation
Blank flash
Reference mark detected (visible indication at speed <100 mm/s only)
4 red flashes
Low signal, over signal, or overspeed; system in error
Yaw
0° ±0.9°
Pitch
0° ±1°
Status
Roll
0° ±0.8°
Rideheight
1.9 ±0.17 mm
from FASTRACK
top surface
11

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

Quantic rtlc40/fastrackQuantic rtlc40Quantic fastrack

Table of Contents