Table of Contents
Table of Contents
2
1 Safety Instructions
5
Basic Information on Safety
5
Range of Application
5
Applications in Ex Zone 22 (Option)
6
Warnings and Notes
6
References and Symbols
7
2 Identification
8
Name Plate
8
Short Description
9
3 Transport, Storage and Packaging
10
Transport
10
Storage
10
Packaging
10
4 Assembly
11
Mounting Position
11
Handwheel Fitting
11
Multi-Turn Actuator: Mount to Valve/Gearbox
12
Output Drive Types B, B1
12
B4 and E
12
Multi-Turn Actuator
12
B4 or E): Mount to Valve/Gearbox
12
Output Drive Type a
13
Stem Nut: Finish Machining
13
Multi-Turn Actuator (with Output Drive Type A): Mount to Valve
14
Accessories for Assembly
15
Stem Protection Tube for Rising Valve Stem
15
Mounting Positions of Local Controls
15
Mounting Positions: Modify
16
5 Electrical Connection
17
Basic Information
17
Connection with AUMA Plug/Socket Connector
19
Terminal Compartment: Open
19
Cable Connection
20
Terminal Compartment: Close
21
Bus Terminal Compartment: Open
21
Bus Cables: Connect
22
Bus Terminal Compartment: Close
25
Accessories for Electrical Connection
25
Controls Mounted to Wall Bracket
25
Parking Frame
26
Protection Cover
27
Double Sealed Intermediate Frame
27
Earth Connection, External
27
6 Operation
28
Manual Operation
28
Manual Operation: Engage
28
Manual Operation: Disengage
28
Motor Operation
29
Local Operation
29
Operation from REMOTE
30
Menu Navigation Via Push Buttons (for Settings and Indications)
30
Short Overview: Functions of the Push Buttons
31
Structural Design and Navigation
31
Password Entry
32
Language Change in the Display
32
7 Indications
34
Status Indications in the Display
34
Status Indication S0/S6 - Operation
34
Torque Indication: Edit
35
Indication Lights/Leds
35
Mechanical Position Indicator/Running Indication
36
8 Signals
37
Signals Via Fieldbus
37
Feedback Signals Via Output Contacts (Binary)
37
Feedback Signals (Analogue)
37
9 Commissioning (Basic Settings)
38
Heat-Up Time for Low Temperature Version
38
Type of Seating: Check/Edit for End Positions
38
Baud Rate, Parity and Bus Addres (Slave Addess): Set
42
Further Parameters of the Modbus Interface
45
Switch Compartment: Open
45
Torque Switching: Set
46
Limit Switching: Set
46
End Position CLOSED (Black Section): Set
47
End Position OPEN (White Section): Set
47
Intermediate Positions: Set
48
Running Direction CLOSE (Black Section): Set
48
Running Direction OPEN (White Section): Set
48
Test Run
49
Direction of Rotation: Check
49
Limit Switching: Check
50
Reference Operation Position Feedback: Perform
50
Potentiometer Setting
51
Electronic Position Transmitter RWG: Set
51
Mechanical Position Indicator: Set
52
Switch Compartment: Close
53
Corrective Action
54
Faults During Commissioning
54
Fault Indications and Warning Indications
54
Status Indication S0 - Faults and Warnings
55
Status Indication S1 - Faults
55
Status Indication S2 - Warnings
56
Status Indication S3 - Causes for Not Ready Remote
57
Fuses
57
Fuses Within the Actuator Controls
57
Motor Protection (Thermal Monitoring)
58
Servicing and Maintenance
60
Preventive Measures for Servicing and Safe Operation
60
Maintenance
60
Disposal and Recycling
61
Technical Data
62
Features and Functions of Actuator
62
Features and Functions of Actuator Controls
63
Modbus Interface
66
Service Conditions
67
Accessories
68
Further Information
68
Spare Parts
69
Multi-Turn Actuators SA
69
Sa 16.1/Sar 07.1
69
Actuator Controls AUMATIC AC 01.1 with AUMA Plug/Socket Connector (SD Bus)
71
Certificates
73
Declaration of Incorporation and EC Declaration of Conformity
73
Index
76
Addresses
78
Advertisement
AUMA SAR 07.1 Operation Instructions Manual (72 pages)
Multi-turn actuator/Intrusive with actuator controls AUMATIC AC 01.1
Brand:
AUMA
| Category:
Controller
| Size: 1 MB
Table of Contents
Table of Contents
2
1 Safety Instructions
5
General Notes on Safety
5
Range of Application
6
Applications in Ex Zone 22 (Option)
7
Warnings and Notes
8
Further References and Symbols
8
2 Identification
9
Name Plate
9
Short Description
11
3 Transport, Storage and Packaging
12
Transport
12
Storage
12
Packaging
12
4 Assembly
13
Handwheel Fitting
13
Multi-Turn Actuator Mounting to Valve/Gearbox
14
Output Drive Types B1, B2, B3, B4, B, and E
14
Output Drive Type a
15
Accessories (Option)
17
Protection Tube for Rising Valve Stem
17
Mounting Positions of the Local Controls
18
5 Electrical Connection
19
General Notes
19
Connection with AUMA Plug/Socket Connector (S, SH, SE)
20
Accessories for Electrical Connection (Option)
23
Controls Mounted to Wall Bracket
23
Parking Frame
24
Protection Cover
24
Double Sealed Intermediate Frame
24
Ground Connection, External
24
6 Operation
25
Manual Operation
25
Motor Operation
26
Local Operation
26
Operation from REMOTE
26
Menu Navigation Via Push Buttons (for Settings and Indications)
27
Short Overview: Functions of the Push Buttons
27
Structural Design and Navigation
28
Language Change in the Display
29
7 Indications
31
Status Indication in the Display
31
Status Indication S0/S6 - Operation
31
Indication Lights/Leds
32
Mechanical Position Indicator/Running Indication (Option)
32
8 Signals
33
Feedback Via Output Contacts (Binary)
33
Feedback Signals (Analogue) - (Option)
33
9 Commissioning
34
Type of Seating: Check/Edit for End Positions
35
Switch Compartment: Open
38
Torque Switching: Check/Set
39
Limit Switching Setting
40
End Position CLOSED (Black Section) Setting
40
End Position OPEN (White Section) Setting
40
Intermediate Positions (Option) Setting
41
Running Direction CLOSE (Black Section) Setting
41
Running Direction OPEN (White Section) Setting
41
Test Run
42
Rotational Direction Check
42
Limit Switching Check
43
Perform Reference Operation
43
Potentiometer (Option) Setting
44
Electronic Position Transmitter RWG Setting (Option)
45
Mechanical Position Indicator Setting (Option)
46
Switch Compartment: Close
47
10 Corrective Action
48
Faults During Commissioning
48
Mechanical Position Indicator
48
Position Transmitter RWG
48
Limit and Torque Switches
48
Fault in End Position (Overrun Not Considered)
49
Push Buttons Do Not React
49
Fault Indications and Warning Indications
50
Status Display S0 - Faults and Warnings
50
Status Indication S1 - Faults
51
Status Indication S2 - Warnings
52
Status Indication S3 - Causes for Not Ready Remote
53
Fuses
54
Fuses Within the Actuator Controls
54
Motor Protection (Thermal Monitoring)
55
11 Servicing and Maintenance
56
Preventive Measures for Servicing and Safe Operation
56
Maintenance
57
Disposal and Recycling
57
12 Spare Parts List
58
Multi-Turn Actuator SA 07.1 - SA 16.1/SAR 07.1 - SAR
58
Controls AC 01.1 with AUMA Plug/Socket Connector (S, SH, SE)
60
13 Technical Data
62
14 Certificates
68
Declaration of Conformity and Declaration of Incorporation
68
Index
69
Addresses
70
AUMA SAR 07.1 Operation Instructions Manual (48 pages)
Multi-turn actuators
Brand:
AUMA
| Category:
Controller
| Size: 1 MB
Table of Contents
Table of Contents
2
Safety Instructions
4
Basic Information on Safety
4
Range of Application
4
Applications in Ex Zone 22 (Option)
5
Warnings and Notes
5
References and Symbols
6
Identification
7
Name Plate
7
Short Description
7
Transport, Storage and Packaging
8
Transport
8
Storage
8
Packaging
8
Assembly
9
Mounting Position
9
Handwheel Fitting
9
Multi-Turn Actuator: Mount to Valve/Gearbox
10
Output Drive Types B, B1
10
B4 and E
10
Multi-Turn Actuator
10
B4 or E): Mount to Valve/Gearbox
10
Output Drive Type a
11
Stem Nut: Finish Machining
11
Multi-Turn Actuator (with Output Drive A): Mount to Valve
12
Accessories for Assembly
13
Stem Protection Tube for Rising Valve Stem
13
Electrical Connection
14
Basic Information
14
Connection with AUMA Plug/Socket Connector
15
Terminal Compartment: Open
15
Cable Connection
16
Terminal Compartment: Close
17
Accessories for Electrical Connection
18
Parking Frame
18
Protection Cover
18
Double Sealed Intermediate Frame
18
Earth Connection, External
18
Operation
20
Manual Operation
20
Manual Operation: Engage
20
Manual Operation: Disengage
20
Motor Operation
21
Indications
22
Mechanical Position Indicator/Running Indication
22
Signals
23
Feedback Signals from Actuator
23
Commissioning
24
Switch Compartment: Open
24
Torque Switching: Set
24
Limit Switching: Set
25
End Position CLOSED (Black Section): Set
25
End Position OPEN (White Section): Set
26
Intermediate Positions: Set
26
Running Direction CLOSE (Black Section): Set
27
Running Direction OPEN (White Section): Set
27
Test Run
27
Direction of Rotation: Check
27
Limit Switching: Check
28
Potentiometer Setting
29
Electronic Position Transmitter RWG: Set
29
Mechanical Position Indicator: Set
30
Switch Compartment: Close
31
Corrective Action
32
Faults During Commissioning
32
Motor Protection (Thermal Monitoring)
32
Maintenance
33
Preventive Measures for Servicing and Safe Operation
33
Servicing and Maintenance
33
Disposal and Recycling
34
Features and Functions of Actuator
35
Technical Data
35
Service Conditions
36
Further Information
37
Multi-Turn Actuators SA
38
Sa 16.1/Sar 07.1
38
Spare Parts
38
Certificates
40
Declaration of Incorporation and EC Declaration of Conformity
40
Index
43
Addresses
45
Advertisement
AUMA SAR 07.1 Operation Instructions Manual (32 pages)
Electric multi-turn actuators. AUMA NORM for flanges type FA
Brand:
AUMA
| Category:
Controller
| Size: 1 MB
Table of Contents
Table of Contents
2
1 Safety Instructions
4
Commissioning (Electrical Connection)
4
Maintenance
4
Range of Application
4
2 Short Description
4
Warnings and Notes
4
3 Technical Data
5
Packaging
7
Storage
7
Transport
7
4 Transport, Storage and Packaging
7
5 Mounting to Valve/Gearbox
8
6 Manual Operation
10
Connection with AUMA Plug/Socket Connector
11
7 Electrical Connection
11
Controls Made by AUMA
12
Delay Time
12
Heater
12
Motor Connection for Special Motors
12
Motor Connection for the Sizes SA(R) 25.1/SAR 30.1 - SA
12
Motor Protection
12
Remote Position Transmitter
12
Fitting of the Cover
13
Limit and Torque Switches
13
8 Opening the Switch Compartment
14
Pulling off the Indicator Disc (Option)
14
Removing the Switch Compartment Cover
14
Checking the Limit Switches
15
Setting the End Position CLOSED (Black Section)
15
Setting the End Position OPEN (White Section)
15
9 Setting the Limit Switching
15
Checking the DUO Switches
16
Setting the Direction CLOSE (Black Section)
16
Setting the Direction OPEN (White Section)
16
10 Setting the DUO Limit Switching (Option)
16
Checking the Torque Switches
17
Setting
17
11 Setting the Torque Switching
17
Check Direction of Rotation
18
Check Limit Switching
18
12 Test Run
18
13 Setting the Potentiometer (Option)
19
14 Setting the Electronic Position Transmitter RWG (Option)
20
Setting for 2-Wire System 4 - 20 Ma and 3-/4-Wire System 0 - 20 Ma
21
Setting the 3-/4- Wire System 4 - 20 Ma
22
Advertisement
Related Products
AUMA SAR 07.2
AUMA SAR 07.1 - SAR 30.1
AUMA SAR 07.5
AUMA SAR 07.6
AUMA SAR 07.2-UW
AUMA SAR 07.6-UW
AUMA SARV 14.2
AUMA SARI 50
AUMA SAREx 16.2 KT/KM
AUMA SAR 14.2-UW
AUMA Categories
Controller
Industrial Equipment
Control Unit
Control Systems
Outboard Motor
More AUMA Manuals
Login
Sign In
OR
Sign in with Facebook
Sign in with Google
Upload manual
Upload from disk
Upload from URL