Fagor Edesa 2006 Technical Manual page 22

Table of Contents

Advertisement

t e c h n i c a l
Description of operation
3.6.4.- Imbalance Operation
1. - Spin attempts
If an imbalance is detected, the present phase will restart at second 25.
The number of attempts is limited to 18 (15 minutes).
After 18 spin attempts, it checks whether the imbalance level is lower than the high
imbalance level (1520 g).
If it is lower, follow the spin sequence but limit the speed to C1 (minimum spin speed
position on the rpm selector).
The number of attempts here is 2. If it also fails to start after these two attempts,
move to the next programme step.
The spin time indicated in the steps of the electronic programmer is not reduced by
the spin attempts in which an imbalance is detected.
2. - Reading the pressure switch
If the pressure switch is activated when the spin peak between imbalance readings
1, 2 and 3 is reached, the machine continues to spin normally until the next
imbalance reading.
If the pressure switch is activated during any other spin, the motor stops and wait
until you read "empty" on the pressure switch. The current phase will then restart.
The spin time indicated in the steps of the electronic programmer is not reduced by
waiting to read "empty" on the pressure switch
3.- Spinning in the TSS programme
Spinning in the TSS programme does not include the fi rst 42 seconds of the spin
cycle.
4. – Skip spin
It will perform a Very Delicate Spin for 60 seconds.