Components - Fagor Edesa 2006 Technical Manual

Table of Contents

Advertisement

t e c h n i c a l

3.4.- Components

Component
NTC Safety Thermostat
NTC
Resistance thermostat
Component
Motor
Door lock
Safety
Description of operation
Function
Used in machines with
variable spin and makes
rotating movements when
washing and spinning.
Motor power supply:
- Clockwise, power 220V.
, contacts 2 and 3. Bridge
between contacts 5 and 6.
- Anti-clockwise, power
220V. , contacts 3 and 5.
Bridge between contacts 2
and 6.
Opens hatch lock
The electronic card
reads the NTC (variable
resistance), and
determines whether the
water temperature has
reached the selected
temperature in the
programme to complete
the heating phase
10
Features
Voltage: 220V / 50 Hz
Stator resistance: 1.3 Ω
Rotor resistance: 1.7 Ω
Tachogenerator
resistance: 184 Ω
Tachogenerator voltage:
1.2 V / 1,000 rpm
Voltage: 220 V /
50 Hz 16 Amp.
Between 40 and
75 second delay
NTC (see values in the
table)
Safety thermostat
Heating
resistance
96 ºC
96ºC Contact normally
closed
-20ºC Thermostat resets

Hide quick links: