t e c h n i c a l
3.5.- Fagor circuit confi guration:
3.1.3.- Fagor circuit configuration:
If the circuit is not configured, it will go into
(go to step no. 7). If the circuit is configured it enters the current configuration.
To change the configuration, follow these steps:
1.- Turn the machine off
2.- Press the start / pause button
3.- Press the
4.- Press the spin button
on the LCD screen
5.- Release all keys simultaneously
6.- The door lock will be locked
7.- Press the spin button
(the last digit of the LCD will flash).
8.- Pressing the Time Delay button changes the parameter to be adjusted,
starting with the KG digit and following the sequence:
KG – RPM – RECIRCULATION – COLD WATER – DOOR OPENING– KG - ........
Pressing the SPIN button changes the value of the parameter; the possible values
are limited to the circuit's hardware reference and the selected KGs. If the KGs
are changed after having selected the RPM, and the previous RPM value is not
permitted for the newly selected KGs, the RPM will re-adjust to the value closest
for the newly selected KGs.
button for 1 second until the LCD screen lights up
and wait 2 seconds until the letter
Select
1200
RECIRCULATION PUMP
RPM
YES 00 / NO 0
Description of operation
status as soon as it is plugged in
and keep it pressed (until step 5)
and the configuration digits are displayed
COLD WATER
YES 0 / NO 8
13
is displayed
Select
DOOR OPENING
YES 8 / NO 0
KG
6