t e c h n i c a l
3.6.2.- Seguridades criterios
SAFETY
MECHANISMS
FILLING
UNBALANCED
NO HEATING
EMPTYING
OVERFULL
DOOR LOCK
PROGRAMME
SELECTOR
MOTOR
INVERSION
WITH MOTOR
STOPPED
B= pending increase in temperature when heating
FAULT CONDITION
EV ON 8 min. and PN
F01
OFF (empty)
(except in reliability
programme)
Detects imbalance in
F03
18 attempts (15 min)
of low imbalance level
(see spin table)
NTC
NTC in short circuit or
F05
open circuit
B < 5º C / 15 min.
F06
(excepto en programa
fiabilidad)
EB ON 6 min. and PN
F02
ON (full)
Drainage pump cuts
F07
out or loses electricity
supply
Electronic operated
F07
valve cuts out
Door lock ON and
F04
also detects failure
of both control triacs
of the door lock (both
open)
Selector in short
circuit or open circuit
F08
Tachogenerator
F09
motor lock fault (three
consecutive attempts)
Does not invert the
direction until the
motor stops (Max.
F10
time (1 min.)
Description of operation
WASHER ACTION
It remains on pause with
door lock ON
It performs 2 attempts
with the high imbalance
level, limiting the speed
to C1.
Even if it spins at this
speed, it will indicate the
fault (see spin table).
It performs the selected
programme but without
heating
STOP
(End of programme)
Performs DELICATE cold
programme (only in User
Mode)
STOP
End of programme
Door lock always closed
17
RESET
(End of safety)
Any of these conditions
resets the safety:
1. – Power is lost (supply
or ON/OFF switch).
2.- Change of programme
selector position.
The fault indicator disap-
pears, as in previous
cases but the door lock is
kept closed.
To unlock it, keep it OFF.