Product Technical Specification
1.7.
ESD
Refer to the following table for ESD Specifications.
Table 3.
ESD Specifications
Category
Operational
Non-operational
Signals
1.8.
Environmental and Certifications
1.8.1.
Environmental Specifications
The environmental specification for both operating and storage conditions are defined in the table
below.
Table 4.
Environmental Specifications
Conditions
Operating Class A
Operating Class B
Storage
Class A is defined as the operating temperature ranges that the device:
•
Shall exhibit normal function during and after environmental exposure.
Shall meet the minimum requirements of 3GPP or appropriate wireless standards.
•
Class B is defined as the operating temperature ranges that the device:
Shall remain fully functional during and after environmental exposure
•
•
Shall exhibit the ability to establish an SMS or DATA call (emergency call) at all times even
when one or more environmental constraint exceeds the specified tolerance.
•
Unless otherwise stated, full performance should return to normal after the excessive
constraint(s) have been removed.
41110555
Connection
Specification
RF ports
IEC-61000-4-2 — Level (Electrostatic Discharge Immunity Test)
Unless otherwise specified:
Host connector
interface
SIM connector
Adding ESD protection is highly recommended at the point where
the USIM contacts are exposed, and for any other signals that
Other host signals
would be subjected to ESD by the user.
Rev 1.0
•
JESD22-A114 ± 1kV Human Body Model (TBC)
•
JESD22-A115 ± 200V Machine Model (TBC)
•
JESD22-C101C ± 250V Charged Device Model (TBC)
Range
-30°C to +70°C
-40°C to +85°C
-40°C to +85°C
Introduction
November 01, 2017